×

:

Not a valid Time
This is a required field.

Amron Remote Two-Way Speaker w/PTT Switch

SHIP NOW
SKU
3110
$635.00
Eligible for Free Shipping Over $125
Remote two-way speaker provides paging (both calling and answer pages) by activating Push-to-Talk switch. Eliminates unnecessary monitoring of high-noise areas. Speaker is 15 Watts, 8 ohm. Optional headset reduces ambient noise interference. Housing is die cast zinc with gray epoxy powdercoat.
More Information
Features
  • Two-way speaker with call switch provides chamber to dive control communication.
  • Headset jack is wired for conference style communications (duplex).
  • Optional headset permits conversation without disturbing other chamber occupants.
  • A Push-to-Call switch activates a call indicator on the Amron Comm Routing Panel (CRP). The CRP activates an audio alarm and a visual indicator identifying the caller's location.

 

Specifications
  • Front Panel Material: Stainless steel
  • Housing Material: Die-cast zinc with gray powder coat
  • 8 Ω
  • 15 watt speaker
  • Dimensions:
    • Height: 5.5 in.
    • Width: 5.5 in.
    • Depth: 4 in.
  • Weight: 5 lb.
  • Includes:
    • 7-pin MS connector - P/N: MS-3106A-16S-1S
    • MS cable clamp 16S-1 - P/N: MS-3057-8A

 

DISCLAIMER NOTICE: Amron's communications equipment is designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Use of our products in high-concentration Oxygen environments may result in serious injury and/or death.

 

2 or 3 year extended warranties are available for this product. Please refer to the Resources tab for further information on the program.

Features
  • Two-way speaker with call switch provides chamber occupant to dive control comms.
  • Push-to-Talk (PTT) toggle switch performs two functions:
    • Hold the switch to talk externally to the dive control operator.
    • Momentarily hold the switch to activate a call indicator on the Amron 3226 Chamber Communications Routing Panel (optional).
  • Headset connection (Neutrik, 4-pin) for full duplex, private communication (headset optional).
  • MS (military style) connector for electrical connections on the speaker box bottom.
  • Speaker box MS connector mates with included MS connector, bushing and clamp.
  • Mount the speaker box using two flanges located on box left and right (for 1/4 in. screws).
  • Durable, die cast, zinc, epoxy powder coated enclosure finish.

 

Specifications
  • Speaker Impedance: 8 Ω
  • Speaker Power: 15 watts
  • Height: 5.5 in. (14.0 cm)
  • Width: 5.5 in. (14.0 cm)
  • Depth: 4.0 in. (10.2 cm)
  • Weight: 5 lb. (2.3 kg)
  • Enclosure: Die cast zinc, powder coat

 

Includes
  • 7-Pin MS (military style) Connector (P/N: MS-3106A-16S-1S)
  • MS Connector Cable Clamp for 16S-1 Shell (P/N: MS-3057-8A)
  • MS Connector Strain Relief Bushing for 16S-1 Shell (P/N: MS-3420-8)

The Amron International Model 3110 Remote Two-Way Speaker w/PTT Switch provides chamber to dive control communication.

 

Two-way speaker. PTT Switch, chamber to Dive Control (DC). Headset jack is wired for conference style communications (duplex). Speaker is 15 watts, 8 ohm.

 

Optional headset permits conversation without disturbing other chamber occupants. Individual connections for headset and speaker allow DC to continue chamber monitoring while communicating with a person using the headset.

 

Housing is die cast zinc with gray epoxy powdercoat.

 

DISCLAIMER NOTICE: Amron's communications equipment is designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Use of our products in high-concentration Oxygen environments may result in serious injury and/or death.

 

2 or 3 year extended warranties are available for this product. Please refer to the Resources tab for further information on the program.

Communications using Amron’s model 3110 Remote Two-Way Speaker are accomplished by using the Push-to-Talk (PTT) toggle switch and speaker, or by connecting a headset to the Neutrik style connector (4-pin) on the side of the box. Headset communication provides hands-free, full duplex communications and permits conversation without disturbing other chamber occupants. Amron’s 2401-31R Deluxe Headset and 2460-31R Standard Headset come pre-configured with a Neutrik style 4-pin connector that works directly with the 3110 speaker and headset connector.

 

The PTT switch doubles as a call switch when using Amron’s 3226 Chamber Communications Routing Panel (optional). Momentarily holding the switch activates a call indicator on the 3226 comm routing panel. The 3226 call indicator is both an audio alarm and a visual indicator that identifies the caller's location in the chamber.

 

Electrical wiring exits the box at the bottom through the 7-pin MS (military style) connector. Included with the 3110 speaker is separate MS connector that mates with the connector on the bottom of the 3110 speaker box. This separate MS connector (P/N MS-3106A-16S-1S) comes with a cable clamp (P/N MS-3057-8A) and strain relief bushing (P/N MS-3420-8) and provides for organized and easy chamber wiring.

 

The durable, die cast, zinc, powder coated 3110 speaker box is mounted using two flanges located on the left and right of the box using 1/4 in. screws.

 

DISCLAIMER NOTICE: Amron's communications equipment is designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Use of our products in high-concentration Oxygen environments may result in serious injury and/or death.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!