Not a valid Time
This is a required field.

Amron Chamber Communication Routing Panel

SKU
3226
$9,869.00
Eligible for Free Shipping Over $125

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
More Information

Amron’s Model 3226 Communication Routing Panel provides a complete communications solution for managing and monitoring communications and signaling within a Deck Decompression Chamber (DDC) of a saturation diving system for a maximum of 12 divers. The operator uses the routing panel to interconnect various comm sources within the system and to monitor audible and visual signals sent from any of the comm boxes within the chamber.

 

Features
  • Twelve bunk station channels, arranged in two chambers, six stations per chamber.
  • Two communication station channels per chamber: One chamber, one entry lock with push to call.
  • Two helium unscrambler channels. Each can be used as primary communication or split for two independent conversations.
  • Two entertainment channels with two audio sources per channel.
  • Audio/visual call indicator for each chamber location.
  • Operator can route private or conference conversation through one helium unscrambler, leaving the other for chamber monitoring.
  • Includes a noise-canceling hand-held microphone for operator.

 

Specifications
  • Call Circuit Channels: 16 each, 8 per chamber (6 bunk boxes, 1 comm. box, and 1 entry lock)
  • Input/Outputs: MS connectors on rear panel (MIL- C- 5015)
  • Enclosure: 19 in. retma rack mount, anodized aluminum
  • Height: 7 in. (17.8 cm)
  • Width: 19 in. (48.3 cm)
  • Depth: 13 in. (33 cm)
  • Weight: 10 lb. (4.5 kg)

 

Chamber Communication Routing Panel - P/N: 3226 Includes
  • Hand-Held Push-to-Talk Microphone - P/N: 2405-28
  • (12) MS Connector Cables 14 Pin Female - P/N: MS-3106A-20-27S
  • (12) MS Cable Clamps 20/22 Shells - P/N: MS-3057-12A
  • (4) MS Connector Cables 7 Pin Male - P/N: MS-3106A-16S-1P
  • (4) MS Cable Clamps 16 Shell - P/N: MS-3057-8A
  • (2) MS Connector Cables 5 Pin Male - P/N: MS-3106A-14S-5P
  • (2) MS Cable Clamps 14 Shell - P/N: MS-3057-6A
  • (2) MS Connector Cables 20 Pin Male - P/N: MS-3106A-28-16P
  • (2) MS Cable Clamps 24/28 Shells - P/N: MS-3057-16A
  • (2) MS Connector Cables 4 Pin Female - P/N: MS-3106A-14S-2S
  • (2) MS Cable Clamps 14 Shell - P/N: MS-3057-6A
  • (1) Power Cord - P/N: P-2392
  • User Manual

 

DISCLAIMER NOTICE: Amron's chamber communications are designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Misuse of our chamber communicator products in high-concentration Oxygen environments may result in serious injury and/or death.

Amron’s Model 3226 Communication Routing Panel is designed to control communications for a Deck Decompression Chamber (DDC) used within a saturation diving system. The Model 3226 provides for routing of voice and audio signals between dive control and the saturation chambers. It is essentially a switching panel, allowing the operator to identify the origin of a signal and its routing. The operator uses the routing panel to interconnect various comm sources within the system and to monitor audible and visual signals sent from any of the comm boxes within the chamber.

 

The 3226 allows the operator to manage voice and audio signals to and from individual chamber bunk boxes like Amron’s 3112 Chamber Bunk Box, and general living chamber and entry lock comm boxes such as Amron’s 3110 and 3111 comm boxes, as well as either of Amron’s sound powered phone and headset combo boxes (Model 3125 and 3126) that are used in inner and outer locks. All voice comms originating from any of these comm boxes are routed through Helium Speech Unscramblers (HSU) such as Amron’s 2830R-02 3-Diver Rackmount HSU Communicator for helium speech voice correction. The 3226 comm routing panel also routes entertainment audio (two channels, four sources) from entertainment sources.

 

Amron’s Model 3226 can service a 12-man or smaller diving complex. The largest serviceable arrangement is two 6-man chambers and two entry locks. The chambers are designated Chamber A and Chamber B. All system input/output interconnects are via the rear panel MS connectors (military standard). See the 3226 user manual for typical chamber and comm box wiring configurations.

 

DISCLAIMER NOTICE: Amron's chamber communications are designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Misuse of our chamber communicator products in high-concentration Oxygen environments may result in serious injury and/or death.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!