Request a Quote

Please fill out the following form below.

Amron International Amcom ™ II 2-Diver Deluxe Portable Rechargeable Communicator with External Charger

SKU: 2825A/23 Rate this product

$2,085.00

Availability: Contact us for availability

Click to Enlarge Image

Overview

Features

  • Volume setting for each diver and tender to their individual comfort level
  • Both divers can be set up on 4-Wire Mode or 2-Wire Mode or any combination of the two modes
  • Ability to use both dynamic and pre-amplified diver microphones with a unique circuit that detects microphone type and automatically adjusts volume levels
  • Weatherproof panel microphone for greater voice intelligibility
  • Communicator can be left on charge indefinitely without damage to the batteries or communicator (/23 and /24 versions only)
  • Communicator can be operated directly from the charger where AC power is available (/23 and /24 versions only)

Rechargeable with External Charger: Part Number 2825A/23 Includes

Specifications

  • Audio Power Output: 22 Watts per channel
  • Frequency Response: 300Hz to 12kHz
  • Isolation Transformer: Split Bobbin Medical Grade
  • Dimensions: 10 in. H x 9 in. W x 14.5 in. L (25.4 cm x 22.9 cm x 36.8 cm)
  • Weight: 22.5 lbs (10.2 kg)
  • Power: 110/220VAC 50/60 Hz (automatic sensing), or Internal/External Batteries 12VDC (/23 and /24 versions only)

Available Option

Tech Note

All communicators will transfer topside noise to the diver when using the radio speaker only. To eliminate background noise and achieve clear concise communications, use a Push-to-Talk microphone, headset, or a Remote Walk-and-Talk with a headset.

2 and 3 Year Extended Warranties are available for this product.Please refer to the Attachments tab for further information on the warranty programs.

Descriptions

The Amron International Amcom ™ II 2-Diver Deluxe Portable Rechargeable Communicator with External Charger is the most versatile and powerful two diver communicator on the market today. The most unique feature is the design of separate channels and volume controls for each diver and the tender, both for the uplink and the downlink paths. Each diver may have different equipment such as microphones and speakers or different listening and speaking characteristics. You can set the volume for each diver and tender to their individual comfort level. Both divers can be set up on 2-wire and/or 4-wire mode, or one diver on 4-wire mode and the other on 2-wire mode or any combination of the two modes.

Attachments
Videos

Additional Information

Brand Amron International
Communication Mode 2-wire/4wire
Video No
FAQ
 

Product FAQ's

Ask a Question

  • Can you stack the banana plugs from the diver's communicators cable so you can have two divers on each diver channel?

    Although it may be possible, we stronly discourage such operation. The added workload would cause overheating and stress to the amplifier card. Prolonged use in this condition will eventually cause perment damage and failure to the amplifier card.

    How helpful was this information?

  • Should I use a GFI when operating my radio off AC power?

    When operating your Amron Diver Communicator on AC, it is critical to use a Ground Fault Circuit Interrupter (GFCI) or isolation transformer for tender and diver safety. Surges and spikes are common on AC lines found on ships, generated locally, or at the end of long extension cable runs and can exceed 1kVolt. Such surges and spikes can cause the fuses, F1 and F2, to blow on the battery charger board and in extreme cases damage the charger circuitry. The battery charger is designed so that such a failure will be isolated and will not cause a safety issue to the tender or divers. It is strongly advised that your Amron Diver Communicator be operated on an AC circuit with a high quality surge arrester or an AC isolation transformer.

    How helpful was this information?

  • When my battery does not appear to be holding a charge, how do I know if the problem is a bad battery or if the charger is broken?

    To determine whether the problem is with the battery or charger you will need to verify if the charger is properly charging the battery.
    Troubleshooting: Unplug your communicator and turn on the POWER switch. Measure the voltage across the yellow PUSH-TO-TALK (PTT) jack and write down this value for future reference. It should be greater than 9 Volts. Plug the communicator into an AC source and verify that the AC POWER LED on the front panel turns on. Re-measure the voltage across the PTT jack and note it down for future reference. It should be higher than the previous measurement. If this AC POWER LED does not light up when the communicator is plugged in, then check fuses F1 and F2 on the charger Printed Circuit Assembly (PCA). Allow the communicator to charge overnight. Unplug the communicator and re-measure the voltage across the PTT jack. If it is the same or less than the voltage you measured previously, then the charger is broken and the communicator needs to be sent in for repairs If it is the same or less than the voltage you measured previously, then the charger is broken and the communicator needs to be sent in for repairs. If the voltage higher than previous measurement but less than 13.5 Volts, then the battery is bad and needs to be replaced. If it is greater than 13.5 Volts but it still appears that the battery is not holding a charge, contact Amron for additional support. less than 13.5 Volts, then the battery is bad and needs to be replaced. If it is greater than 13.5 Volts but it still appears that the battery is not holding a charge, contact Amron for additional support.

    How helpful was this information?

  • How can I test for a blown fuse on my Amcom II series communicator?

    If the unit is plugged into a live outlet and turning on the switch does not cause the AC POWER LED to light up, then the fuse(s) are probably blown. Unplug the unit from the outlet, remove the fuses and check continuity with a multimeter. Replace any fuse that does not show continuity.

    How helpful was this information?

  • How do I install a new microphone in my Amcom II Communicator?
    Please refer to the Panel Microphone Installation instructions located in the attachments tab.
    How helpful was this information?

  • Can my Amcom communicator work on 240V / 60Hz?
    Yes, the unit will operate on 240V 50/60Hz.
    How helpful was this information?

  • Can I operate my communicator while I’m charging the internal battery?
    Yes, however, the charger will charge the battery at a slower rate as some of the charger power is being used to operate the communicator. For the communicator only, units without options, about 20% of the charger’s power is being used by the communicator but units with HSU (Helium Speech Unscrambler) most of the battery charger energy is going to the communicator and HSU.
    How helpful was this information?

  • What is the input voltage range for the 2823-603 External Battery Charger?
    The 2823-603 can operate over an input voltage range from 90-264 VAC. It operates over an input frequency range from 47-440 Hz.
    How helpful was this information?

  • Why does the speaker on my communicator sound muffled?
    The simplest way to fix this issue is to unplug the red banana plug from the red microphone 5-way binding post on the communicator and rotate it 180 degrees then reinstall it. This should fix your problem. For a more detailed explanation of what happened, please read below. The issue is not with the communicator, it is with the wiring of the umbilical. There is always the potential for wiring the speakers and microphone out of phase, similar to wiring the speakers on a car stereo system. There is an orientation to the banana jacks and they should be wired for proper phasing with the communicator. A banana plug does have an identified ground side marked on the plug. Amron always sets up their umbilicals so that the ground side is located on the left side so the user can consistently plug in their umbilical and avoid phasing issues. If a banana plug is plugged upside down or is wired out of phase, the sound quality will be significantly reduced. If the phasing is out and the orientation of both plugs are the same, then the banana plug wiring should be reversed on “only one plug” to avoid this issue again. It does not matter which plug you choose to reverse the wiring on.