×

:

Not a valid Time
This is a required field.

Amron Oxygen Treatment Hood Neck Ring

SHIP NOW
SKU
8891-011
$38.00
Eligible for Free Shipping Over $125

Amron International’s Oxygen Treatment Hood Neck Ring is for use with Amron’s Oxygen Treatment Hood with Optical Viewing Window.

Restrictions / Notifications

  • CA PROP65
    Warning: Cancer and Reproductive Harm www.p65warnings.ca.gov
  • MSDS
    Safety Data Sheet available online or by request.
More Information
Specifications
  • Does not come with P/N: 8891-25 Multipurpose Plug or P/N: 8891-15 O-ring (for complete Neck Ring Assembly, please click here: P/N: 8891-07)
  • U.S. Patent: 9,931,482
  • Neck Ring Material: Polycarbonate (autoclavable)
  • For use with: Amron O2 Vinyl Hood with Optical Window
  • Patented oblong shape
  • Larger opening makes it easier to place over patient’s head
  • Patented two square neck seal groove design
  • Color: White
  • Replaces P/N: 8891-001
 
Compatibility
  • Silicone Neck Seal 8891-009-00 is NOT compatible with OLD Neck Ring P/N: 8891-001
  • Silicone Neck Seal 8891-009-00 is ONLY compatible with 2014 improved Neck Ring P/N: 8891-011
  • Latex Neck Seals (Trimmed P/N: 8891-005 and Untrimmed P/N: 8891-005-00) are compatible with BOTH OLD Neck Ring (P/N: 8891-001) and 2014 improved Neck Ring (P/N: 8891-011)
  • Both versions of the Oxygen Treatment Hood P/N: 8891-010 fit BOTH OLD and 2014 improved Neck Rings
  • Compatible with Models 8891, 8892, 8893 & 8891-010
Specifications
  • For use with Amron’s hyperbaric oxygen treatment hood product series.
  • Large, oblong-shaped neck ring opening makes it easier to place over patient’s head.
  • Neck Ring Material: White Polycarbonate (autoclavable)
  • Two neck seal bead grooves for use in attaching either silicone or latex neck seals.
  • Does not come with P/N: 8891-25 Multipurpose Plug or P/N: 8891-15 O-ring (for complete Neck Ring Assembly, please click here: P/N: 8891-07).
  • U.S. Patent 9,931,482

 

Compatibility
  • Any version of Amron’s hyperbaric oxygen treatment hood P/N: 8891-010 is usable with both OLD Neck Rings (P/N: 8891-001) and current Neck Rings (P/N: 8891-011).
  • The 8891-011 neck ring is usable with Amron’s hyperbaric oxygen hood model series 8891, 8892, 8893 & 8891-010 hoods.
  • Silicone Neck Seal P/N: 8891-009-00 is only usable with Amron’s current Neck Ring P/N: 8891-011.
  • Silicone Neck Seal P/N: 8891-009-00 cannot be used with Amron’s OLD Neck Ring P/N: 8891-001.
  • Latex Neck Seal P/N: 8891-005-00 is usable with both the OLD Neck Ring (P/N: 8891-001) and current Neck Ring (P/N: 8891-011).

Amron International’s patented Oxygen Treatment Hood Neck Ring is for use with Amron’s Oxygen Treatment Hood with Optical Viewing Window.

 

The oblong shaped neck ring is larger than its predecessor, making it much easier for the attendant to place the Amron hoods over the patient’s head (essentially the larger neck ring now has a universal fit where one size fits all patients). The redesigned neck ring now has two square neck seal grooves on it, which provides for a more secure attachment of the neck seal to the neck ring.

 

The neck ring was developed to withstand multiple cycles in an autoclave, gas sterilized or cleaned using SaniZide disinfectant provided by Amron. The reusable neck ring has a conveniently located multipurpose plug port as well as supply and exhaust hose ports, with an accompanying O-ring seal for the vinyl hood attachment. The supply and exhaust locations allow oxygen to circulate easily through the hood at reduced noise levels.

 
Notes
  • The 8891-15 O-Ring and 8891-25 Multipurpose Plug do not come installed on the 8891-011 Neck Ring. For complete Neck Ring Assembly, please click here - P/N: 8891-07 Neck Ring Assembly.
  • U.S. Patent: 9,931,482

Amron’s patented Oxygen Treatment Hood Neck Ring is a replacement part for use with Amron’s hood assemblies used to administer gas, oxygen, air, and humidification to a patient during Hyperbaric Oxygen Therapy (HBOT).

 

Amron’s unique, oblong-shaped neck ring opening makes it easy for the hyperbaric treatment center attendant to place the neck ring over a patient’s head. The large neck ring opening essentially provides a universal fit where one size fits all patients. The neck ring has two square neck seal bead grooves that provide for easy and secure attachment of either a silicone or latex neck seals.

 

The polycarbonate neck ring material can withstand multiple cycles in an autoclave. It can also be cleaned using gas sterilization or using Safetec SaniZide disinfectant recommended by Amron. The neck ring has a conveniently located multipurpose plug port as well as supply and exhaust hose ports, with an accompanying O-ring seal for attachment to the 8891-010 oxygen treatment hood. The supply and exhaust locations allow oxygen to circulate easily through the hood at reduced noise levels.

 

The hose port outside diameters are 22 mm and work with all standard 22 mm tubing, connectors and filters used in clinical environments. Amron offers a variety of medical tubing and connector accessories that can be connected to the ports.

 

NOTES

  • The P/N: 8891-25 Multipurpose Plug and P/N: 8891-15 O-ring do not come installed on the 8891-011 Neck Ring. For a complete Neck Ring Assembly, please click here: P/N: 8891-07.
  • U.S. Patent 9,931,482
FAQ's
Is the new silicone neck seal compatible with the old neck ring system part number 8891-001?
No. The new silicone neck seal is only compatible with the new neck ring system part number 8891-011. The new silicone neck seal has a double square ring base that attaches to the double channel base of the new neck ring system.
Can I purchase an Oxygen Treatment Hood for private use?
No, Federal law (USA) mandates that Amron can only sell this device to physicians and/or licensed clinical practitioners.
Is the Oxygen Treatment Hood Neck Ring autoclavable?

Yes.

What material is the Oxygen Treatment Hood Neck Ring made of?

Polycarbonate.

Can I use my Sterrad ® Sterilization system to sterilize my 8891 Oxygen Treatment Hood?

Amron has not performed any testing to determine whether or not you can use this type of process to sterilize our Oxygen Treatment Hood. Amron recommends using SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner, and deodorizer. 

 

The method of cleaning as stated in the general instructions does not suit our unit due to the clean area that would be required to drip dry the hoods. Is there any other approved method of cleaning?

We only have two methods approved for cleaning.

1)     The first is spraying Sanizide and letting the hood sit for 10 minutes.

2)    The second is gas sterilization using the method below:

  1. Low - 4  hours at 100 degrees Fahrenheit with an aeration time of 36 hours
  2. High - 1 hour at 130 degrees Fahrenheit with an aeration time of 12 hours

Using the gas sterilization will shorten the life of the hood but we have many customers that use it and are very happy with the results.

 

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!