SterilizationPlease reference the User Manual located in the Resources Tab on this web page for recommended cleaning instructions. Amron recommends SaniZide Plus as a convenient, fast-acting germicidal disinfectant. Gas sterilization can be used if close attention is paid to temperature, but multiple cycles of gas sterilization will shorten the working life of the product. Gas sterilization temperatures must be kept below 130°F to avoid affecting the shape of the hood ring. See the FAQ tab on this web page for additional information about gas sterilization.
Oxygen Treatment Hood Neck Ring Assembly - P/N: 8891-07 Includes
Features
Compatibility
SterilizationPlease reference the User Manual located in the Resources Tab on this web page for recommended cleaning instructions. Amron recommends SaniZide Plus as a convenient, fast-acting germicidal disinfectant. Gas sterilization can be used if close attention is paid to temperature, but multiple cycles of gas sterilization will shorten the working life of the product. Gas sterilization temperatures must be kept below 130°F to avoid affecting the shape of the hood ring. See the FAQ tab on this web page for additional information about gas sterilization.
Oxygen Treatment Hood Neck Ring Assembly - P/N: 8891-07 Includes
|
Amron International’s patented Oxygen Treatment Hood Neck Ring Assembly with Multipurpose Plug and O-Ring is for use with Amron’s Oxygen Treatment Hood with Optical Viewing Window.
The oblong shaped neck ring is larger than its predecessor, making it much easier for the attendant to place the Amron hoods over the patient’s head (essentially the larger neck ring now has a universal fit where one size fits all patients). The redesigned neck ring now has two square neck seal grooves on it, which provides for a more secure attachment of the neck seal to the neck ring.
The neck ring was developed to withstand multiple cycles in an autoclave, gas sterilized or cleaned using SaniZide disinfectant provided by Amron. The reusable neck ring has a conveniently located multipurpose plug port as well as supply and exhaust hose ports, with an accompanying O-ring seal for the vinyl hood attachment (Note: The 8891-07 Neck Ring, 8891-15 O-ring, and 8891-25 multipurpose plug come installed together as a set on the 8891-07 Neck Ring Assembly). The supply and exhaust locations allow oxygen to circulate easily through the hood at reduced noise levels. As a soft flow of gas helps to cool the patient, the optical-quality viewing window is continuously being defogged.
Note: U.S. Patent 9,931,482
FAQ's
Yes.
Polycarbonate.
Amron has not performed any testing to determine whether or not you can use this type of process to sterilize our Oxygen Treatment Hood. Amron recommends using SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner, and deodorizer.
We only have two methods approved for cleaning.
1) The first is spraying Sanizide and letting the hood sit for 10 minutes.
2) The second is gas sterilization using the method below:
- Low - 4 hours at 100 degrees Fahrenheit with an aeration time of 36 hours
- High - 1 hour at 130 degrees Fahrenheit with an aeration time of 12 hours
Using the gas sterilization will shorten the life of the hood but we have many customers that use it and are very happy with the results.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone