×

:

Not a valid Time
This is a required field.

Amron Silicone Neck Seal - Untrimmed

SHIP NOW
SKU
8891-009-00
$74.00
Eligible for Free Shipping Over $125
More Information
Features
  • U.S. Patent 9,931,482
  • Patented integrated double square o-rings for easy replacement.
  • Patented raised numbered trim rings for accurate neck sizing.
  • Material: Medical grade silicone (latex-free)
  • Supplied untrimmed
  • High stretch
  • Tear resistant
  • Thicker near the neck ring base for increased durability.
  • Thinner near the top for user comfort.
  • Cleaning methods: Autoclave, gas sterilization, Gama, or disinfection
  • Color: Light blue

 

Installation
  • Installation of silicone neck seal is easy! Just follow the 6 Simple Steps to Install guide. Click Here

 

Compatibility
  • Silicone Neck Seal 8891-009-00 is ONLY compatible with 2014 improved Neck Ring: P/N 8891-011
  • Silicone Neck Seal 8891-009-00 is NOT compatible with OLD Neck Ring: P/N 8891-001
  • Both versions of the Oxygen Treatment Hood P/N: 8891-010 fit BOTH OLD and 2014 improved Neck Rings

Amron International’s patented Silicone Neck Seal is supplied untrimmed, latex-free and designed with molded in double square rings that interlock with the redesigned 8891-011 neck ring, providing for a highly secure attachment of the neck seal to the neck ring.

 

The redesigned silicone neck seal is produced from the top performing medical grade silicone on the market. Some of the key advantages are durability, tear resistance, high stretch capabilities, and the ability to be cleaned using all processes including Autoclave, gas sterilization, Gama, or disinfection.

 

The neck seal was designed with a thicker base for increased durability while tapering to thinner seal for patient comfort. Amron’s neck seals are supplied with accurate and easy-to-size trim lines that ensures proper patient fit every time.

 

Note: Silicone Neck Seal 8891-009-00 is ONLY compatible with 2014 improved version neck ring: P/N 8891-011 

Note: Silicone Neck Seal 8891-009-00 is NOT compatible with old version neck ring: P/N 8891-001

 

FAQ's
Is the new silicone neck seal compatible with the old neck ring system part number 8891-001?
No. The new silicone neck seal is only compatible with the new neck ring system part number 8891-011. The new silicone neck seal has a double square ring base that attaches to the double channel base of the new neck ring system.
I notice that both the silicone and latex neck seals stretch out around the patient's neck after about 10 uses. Is this normal?
This is normal. For better long-term fit, the technician should trim the neck seal to be a little tight at first so the neck seal will fit comfortably and not be too loose after 10 uses.
Can I purchase an Oxygen Treatment Hood for private use?
No, Federal law (USA) mandates that Amron can only sell this device to physicians and/or licensed clinical practitioners.
Can I use my Sterrad ® Sterilization system to sterilize my 8891 Oxygen Treatment Hood?

Amron has not performed any testing to determine whether or not you can use this type of process to sterilize our Oxygen Treatment Hood. Amron recommends using SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner, and deodorizer. 

 

What is the shelf life of your oxygen treatment hood neck seals?
Both part numbers 8891-005-00 untrimmed and 8891-005 trimmed latex neck seals have a shelf life of 2 years from date of receipt at Amron. Part number 8891-009-00 silicone neck seals have a shelf life of 5 years from date of receipt at Amron.
The method of cleaning as stated in the general instructions does not suit our unit due to the clean area that would be required to drip dry the hoods. Is there any other approved method of cleaning?

We only have two methods approved for cleaning.

1)     The first is spraying Sanizide and letting the hood sit for 10 minutes.

2)    The second is gas sterilization using the method below:

  1. Low - 4  hours at 100 degrees Fahrenheit with an aeration time of 36 hours
  2. High - 1 hour at 130 degrees Fahrenheit with an aeration time of 12 hours

Using the gas sterilization will shorten the life of the hood but we have many customers that use it and are very happy with the results.

 

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!