Amron Oxygen Treatment Hood (Helmet) w/ Optical Window
 
Restrictions / Notifications
-  MSDS
 Safety Data Sheet available online or by request.
| Features
 
 SterilizationPlease reference the Cleaning Manual located in the Resources Tab on this web page for recommended cleaning instructions. Amron recommends SaniZide Plus® as a convenient, fast-acting germicidal disinfectant. Gas sterilization can be used if close attention is paid to temperature, but multiple cycles of gas sterilization will shorten the working life of the product. Gas sterilization temperatures must be kept below 130 degrees F to avoid affecting the shape of the hood ring. See the FAQ tab on this web page for additional information about gas sterilization. 
 Specifications
 | 
Amron International’s 8891-010 Oxygen Treatment Hood (Helmet) with Optical Viewing Window is the leading hood on the market and easily sets the standard for all others.
Amron's Oxygen Treatment Hood (Helmet) was designed for clinical hyperbaric chambers with the patient’s comfort in mind and its ease-of-use for the attendant. The hood is comprised of clear medical-grade vinyl with an optical quality, extra-large viewing window on the front. Cleaning this O2 hood is simpler for the attendant now that the hood is welded to the neck ring, reducing the risk of bacteria being trapped in between the neck ring and hood. Integrated locking ribs allows hood to perform at positive pressures at 40+ cm H2O.
FAQ's
No, we currently only offer this one size.
Amron has not performed any testing to determine whether or not you can use this type of process to sterilize our Oxygen Treatment Hood. Amron recommends using SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner, and deodorizer.
No. Amron recommends SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner and deodorizer. SaniZide Plus is delivered ready to use and requires no mixing.
Adjust all the appropriate flow control devices between 25-50 liters per minute. As the hood inflates, adjust the supply and exhaust flow controls to stabilize the hood pressure.
NOTE: Excessive flow will overinflate the hood, and insufficient flow will collapse the hood. Flow rates will vary with chamber delivery systems, user lung volume, and breathing rate. Proper Oxygen and Carbon Dioxide levels should be verified within the hood through the multi-purpose port and the use of an Oxygen analyzer and Carbon Dioxide analyzer such as the Analox SDA Series O2 and CO2 analyzers or Analox Sub Aspida O2/CO2 monitors
We only have two methods approved for cleaning.
1) The first is spraying Sanizide and letting the hood sit for 10 minutes.
2) The second is gas sterilization using the method below:
- Low - 4 hours at 100 degrees Fahrenheit with an aeration time of 36 hours
- High - 1 hour at 130 degrees Fahrenheit with an aeration time of 12 hours
Using the gas sterilization will shorten the life of the hood but we have many customers that use it and are very happy with the results.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
- 
                                                                                         Amron Oxygen Treatment Hood Neck Ring Assembly with Multipurpose Plug and O-RingSKU: 8891-07SHIP NOW$54.00 Amron Oxygen Treatment Hood Neck Ring Assembly with Multipurpose Plug and O-RingSKU: 8891-07SHIP NOW$54.00
 
     
     
     
     