Amron Hyperbaric Oxygen Treatment Hood Assembly with Untrimmed Silicone Neck Seal, Neck Ring with O-ring, and Multi-Purpose Access Port

SHIP NOW
SKU
8891-03
$197.00
Eligible for Free Shipping Over $125

Amron International’s Hyperbaric Oxygen Treatment Hood (Helmet) Assembly with untrimmed latex neck seal, neck ring with O-ring, and multi-purpose port is the leading oxygen hood on the market and easily sets the standard for all others.

Amron’s hood assembly is a two-piece, multi-patient, reusable device for administering gas, oxygen, air, and humidification to a patient for Hyperbaric Oxygen Therapy (HBOT) applications. The hood was designed for both patient comfort and attendant ease of use. The device can be used for adults, children, and infants under the supervision of professional healthcare staff.

Restrictions / Notifications

  • MSDS
    Safety Data Sheet available online or by request.
More Information

Features:

  • U.S. Patent 9,931,482
  • Two-Piece design allows for quick and easy access to patient without taking off the entire hood assembly
  • Integrated locking feature allows hood to perform at positive pressures up to 40 cm H2O before over-pressurization safety relief of hood is activated.
  • Optimum patient cooling and noise reduction
  • Patented solid neck ring design eliminates the potential of bacteria from being trapped inside the ring, and can be easily cleaned via autoclave, gas sterilization, and germicidal disinfectants.
  • Conveniently located gas and sample lines reduce bulk and improve comfort
  • Innovative design allows patient to recline comfortably
  • Multi-purpose access port for gas analysis, temperature, humidity, etc.
  • Positive O-ring seal between hood and neck ring
  • Soft vinyl hood with optical quality viewing window, phthalate free
  • Replaceable silicone neck seal with pre-sized trim lines

Sterilization:

Please reference the User Manual located in the Attachments Tab on this web page for recommended cleaning instructions. Amron recommends SaniZide Plus® as a convenient, fast-acting germicidal disinfectant. Gas sterilization can be used if close attention is paid to temperature, but multiple cycles of gas sterilization will shorten the working life of the product. Gas sterilization temperatures must be kept below 130 degrees F to avoid affecting the shape of the hood ring. See the FAQ tab on this web page for additional information about gas sterilization.

Component Breakdown:

  • P/N 8891-010: Vinyl Hood with Optical Quality Viewing Window
  • P/N 8891-005-00: Untrimmed Silicone Neck Seal
  • P/N 8891-011: Neck Ring
  • P/N 8891-15: Neck Ring O-ring
  • P/N 8891-25: Multi-Purpose Plug

Caution: Federal law (USA) mandates that Amron can only sell this product to physicians and/or licensed clinical practitioners. Please note that this product cannot be shipped to a residence; only to a hospital, medical facility, or clinic.

Specifications:

  • Neck Ring: Polycarbonate (Autoclavable)
  • Hood Ring: PVC
  • Hood: Double Polished clear vinyl, phthalate free
  • Hood Viewing Window: Press Polished optical quality vinyl, phthalate free
  • Neck Seal: Silicone
  • O-ring, Neck Ring: Nitrile
  • Multi-Purpose Plug: Nitrile
  • Straps: TPU
  • Supply and Exhaust Ports: Male 22 mm
  • Multi-Purpose Access Port: 0.5 in. (1.27 cm) diameter
  • Diameter: 12.5 in. (31.75 cm)
  • Height: 13.5 in. (34.29 cm)
  • Weight: 1.37 lbs. (21.9 oz.)
Features
  • U.S. Patent 9,931,482
  • Two-Piece design allows for quick and easy access to patient without taking off the entire hood assembly
  • Integrated locking feature allows hood to perform at positive pressures up to 40 cm H2O before over-pressurization safety relief of hood is activated.
  • Optimum patient cooling and noise reduction
  • Patented solid neck ring design eliminates the potential of bacteria from being trapped inside the ring, and can be easily cleaned via autoclave, gas sterilization, and germicidal
  • disinfectants.
  • Conveniently located gas and sample lines reduce bulk and improve comfort
  • Innovative design allows patient to recline comfortably
  • Multi-purpose access port for gas analysis, temperature, humidity, etc.
  • Positive O-ring seal between hood and neck ring
  • Soft vinyl hood with optical quality viewing window, phthalate free
  • Replaceable silicone neck seal with pre-sized trim lines

 

Specifications
  • Neck Ring: Polycarbonate (Autoclavable)
  • Hood Ring: PVC
  • Hood: Double Polished clear vinyl, phthalate free
  • Hood Viewing Window: Press Polished optical quality vinyl, phthalate free
  • Neck Seal: Silicone
  • O-ring, Neck Ring: Nitrile
  • Multi-Purpose Plug: Nitrile
  • Supply and Exhaust Ports: Male 22 mm
  • Multi-Purpose Access Port: 0.5 in. (1.27 cm) diameter
  • Diameter: 12.5 in. (31.75 cm)
  • Height: 13.5 in. (34.29 cm)
  • Weight: 1.37 lb. (21.9 oz.)

 

Component Breakdown
  • P/N 8891-010: Vinyl Hood with Optical Quality Viewing Window
  • P/N 8891-005-00: Untrimmed Silicone Neck Seal
  • P/N 8891-011: Neck Ring
  • P/N 8891-15: Neck Ring O-ring
  • P/N 8891-25: Multi-Purpose Plug

 

Please reference the User Manual located in the Attachments Tab on this web page for recommended cleaning instructions. Amron recommends SaniZide Plus® as a convenient, fast-acting germicidal disinfectant. Gas sterilization can be used if close attention is paid to temperature, but multiple cycles of gas sterilization will shorten the working life of the product. Gas sterilization temperatures must be kept below 130 degrees F to avoid affecting the shape of the hood ring. See the FAQ tab on this web page for additional information about gas sterilization.

 

Caution: Federal law (USA) mandates that Amron can only sell this product to physicians and/or licensed clinical practitioners. Please note that this product cannot be shipped to a residence; only to a hospital, medical facility, or clinic.

Amron International’s Hyperbaric Oxygen Treatment Hood (Helmet) Assembly with untrimmed latex neck seal, neck ring with O-ring, and multi-purpose port is the leading oxygen hood on the market and easily sets the standard for all others.

 

Amron’s hood assembly is a two-piece, multi-patient, reusable device for administering gas, oxygen, air, and humidification to a patient for Hyperbaric Oxygen Therapy (HBOT) applications. The hood was designed for both patient comfort and attendant ease of use. The device can be used for adults, children, and infants under the supervision of professional healthcare staff.

 

The two-piece design allows the attendant to quickly and safely remove the hood from the neck ring assembly without disturbing the patient or the supply, exhaust, and access lines, allowing full access to the patient.

 

Amron’s unique hood locking system successfully performs to maximum pressures of 40 cm H2O. The built-in locking system acts as safety feature that protects the user by allowing the hood and neck rings to separate at pressures above 40 cm H2O.

 

The hood is removable and comprised of a clear medical-grade and phthalate-free vinyl with an optical quality viewing window for unmatched clarity. The large oblong-shaped neck ring opening makes it easy for the attendant to place over any patients head regardless of size.

 

The reusable neck ring was designed as the heart of the system and has conveniently located gas supply and exhaust ports and a multi-purpose access port, as well as an O-ring seal for the vinyl hood attachment. The supply and exhaust ports are strategically located to allow for optimum gas circulation, lower CO2 pooling, reduced noise levels, patient cooling, and automatic defogging of the optical quality viewing window. The neck ring is solid to eliminated potential bacteria from being trapped inside and was developed to withstand multiple cycles in an autoclave, gas sterilization, and germicidal disinfectants.

 

Amron’s medical grade silicone neck seal is the best performing in the market with the ultimate in stretch, comfort, tear resistance, and durability. The base of the neck seal is thicker with dual square rings that securely interlock with the neck ring while the material is thinner at the top for patient comfort.  The unique design allows the neck seal to be removed and replaced without having to purchase a new hood. The neck seal has integrated, pre-sized trim lines that correspond to the patient neck size to ensure a proper fit every time.

 

Caution: Federal law (USA) mandates that Amron can only sell this product to physicians and/or licensed clinical practitioners. Please note that this product cannot be shipped to a residence; only to a hospital, medical facility, or clinic.

 

Note: U.S. Patent 9,931,482

FAQ's
Is the new silicone neck seal compatible with the old neck ring system part number 8891-001?
No. The new silicone neck seal is only compatible with the new neck ring system part number 8891-011. The new silicone neck seal has a double square ring base that attaches to the double channel base of the new neck ring system.
I notice that both the silicone and latex neck seals stretch out around the patient's neck after about 10 uses. Is this normal?
This is normal. For better long-term fit, the technician should trim the neck seal to be a little tight at first so the neck seal will fit comfortably and not be too loose after 10 uses.
Can I purchase an Oxygen Treatment Hood for private use?
No, Federal law (USA) mandates that Amron can only sell this device to physicians and/or licensed clinical practitioners.
Do you make the 8891-010 Oxygen Treatment Hood in different sizes?

No, we currently only offer this one size.

What is the internal volume of the Oxygen Treatment Hood?
1533.98 in³.
Is the Oxygen Treatment Hood Neck Ring autoclavable?

Yes.

Can I use my Sterrad ® Sterilization system to sterilize my 8891 Oxygen Treatment Hood?

Amron has not performed any testing to determine whether or not you can use this type of process to sterilize our Oxygen Treatment Hood. Amron recommends using SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner, and deodorizer. 

 

Can I autoclave the my Oxygen Treatment Hood?

No. Amron recommends SaniZide Plus as a convenient, fast-acting intermediate level germicidal disinfectant, cleaner and deodorizer. SaniZide Plus is delivered ready to use and requires no mixing.

What is your official recommended oxygen flow rate for the Amron patient hyperbaric oxygen treatment hood?

Adjust all the appropriate flow control devices between 25-50 liters per minute. As the hood inflates, adjust the supply and exhaust flow controls to stabilize the hood pressure.

NOTE: Excessive flow will overinflate the hood, and insufficient flow will collapse the hood. Flow rates will vary with chamber delivery systems, user lung volume, and breathing rate. Proper Oxygen and Carbon Dioxide levels should be verified within the hood through the multi-purpose port and the use of an Oxygen analyzer and Carbon Dioxide analyzer such as the Analox SDA Series O2 and CO2 analyzers or Analox Sub Aspida O2/CO2 monitors

What is the shelf life of your oxygen treatment hood neck seals?
Both part numbers 8891-005-00 untrimmed and 8891-005 trimmed latex neck seals have a shelf life of 2 years from date of receipt at Amron. Part number 8891-009-00 silicone neck seals have a shelf life of 5 years from date of receipt at Amron.
The method of cleaning as stated in the general instructions does not suit our unit due to the clean area that would be required to drip dry the hoods. Is there any other approved method of cleaning?

We only have two methods approved for cleaning.

1)     The first is spraying Sanizide and letting the hood sit for 10 minutes.

2)    The second is gas sterilization using the method below:

  1. Low - 4  hours at 100 degrees Fahrenheit with an aeration time of 36 hours
  2. High - 1 hour at 130 degrees Fahrenheit with an aeration time of 12 hours

Using the gas sterilization will shorten the life of the hood but we have many customers that use it and are very happy with the results.

 

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!