Features

  • Restart Time Delay - Built in A/C time delay protects compressor against quick recycle of cooling circuit, eliminates blown fuses
  • Removable Covers and Panels - For easy access to reservoir, pump, heater, A/C sight glass and other internal components
  • Recessed Control Panel - Equipped with return and supply temperature gauges, fluid indicator, Heat/Off/Cool switches, Power On/Off/Remote switches
  • Fluid Filler Cover - Removed for access to reservoir fill cap
  • Fluid Power-Remote Panels - "Supply and Return", "Power and Remote" control connector panels are easily relocated to opposite side of unit to accommodate individual installation requirements
  • 300 Series Stainless Steel Enclosure - Perforated 300 series stainless end panels
  • Unit is pre-wired for optional remote control option

Specifications

  • Cooling Capacity: 4000 BTU/hr
  • Heating Capacity: 3000 Watts
  • Fluid Flow Rate: 3 GPM @ 5 psig
  • Fluid Media: 50% Ethylene or Propylene Glycol, 50% Water
  • Power: 220VAC, 60Hz, 1 Phase, 15 Amp

Dimensions

  • Height: 30.25 in. (768.35 mm)
  • Width: 27 in. (685.80 mm)
  • Depth: 19.5 in. (495.30 mm)
  • Weight with Cooling Fluid: 215 lbs. (97.52 kg)
  • Weight without Cooling Fluid: 175 lbs. (79.38 kg)

2 or 3 Year Extended Warranties are available for this product. Please refer to the Attachments tab for further information on the program and the Accessories tab to purchase them.

Descriptions

The Amron External Hyperbaric Chamber Conditioning System (Model 9000-ECS) is the supply source for chilled or heated water which is circulated through the Amron Internal Hyperbaric Chamber Conditioning System (Amron Model 9100-ICS2) or any heating/cooling module using water as the media.

The Amron External Hyperbaric Chamber Conditioning System (Model 9000-ECS) is manufactured specifically for heating and cooling double lock decompression chambers. When used in conjunction with one or more internal units, the Amron External Hyperbaric Chamber Conditioning System provides temperature and humidity control by cooling and dehumidifying, or heating the hyperbaric chamber environment.

Optional Amron Remote Control Switch 9000-RCS  with 25 ft. of cable permits the remote selection of Heat, Cool, or Power-Off. Single switch for easy installation in control console.

2 or 3 Year Extended Warranties are available for this product. Please refer to the Attachments tab for further information on the program and the Accessories tab to purchase them.

Attachments
Videos

Additional Information

Brand Amron International
Video No
FAQ
 

Product FAQ's

Ask a Question

  • Does the 9000-ECS External Hyperbaric Chamber Conditioning System come with the glycol and water cooling media?

    No, prior to operating the system you will have to fill the unit with 50% ethylene or propylene glycol and 50% water. Please note: Do not operate the system without fluid, as the circulating pump requires fluid for lubrication and cooling.

    How helpful was this information?

  • Where can I purchase Ethylene or Propylene Glycol for the 9000-ECS External Hyperbaric Chamber Conditioning System?

    Amron recommends using Sierra automotive antifreeze in a 50/50 mixture. Sierra automotive antifreeze can be purchased at most automotive retail stores.

    How helpful was this information?

  • What size chamber is the 9000-ECS External Hyperbaric Chamber Conditioning System unit able to cool/heat?

    The 9000-ECS Environmental Control System was designed to provide chilled or heated fluid for temperature control of a standard 54” deck decompression chamber but in some situations it can cool/heat chambers as large as 72”. The 9000-ECS is used in conjunction with an internal conditioning unit (heat exchanger) located inside the deck decompression chamber. On systems larger than 54” please use two internal conditioning units or more as needed. 

     

    How helpful was this information?

  • What are the operating temperatures or range of temperatures displayed on the gauges for the heat and cold setting for the 9000-ECS External Hyperbaric Chamber Conditioning System?

    Both gauges have an operating range of 0 to 250 o F (-20 to 120 o C) with an accuracy of +/- 1% of full scale

    How helpful was this information?

  • How do I drain the fluid/antifreeze out of the reservoir?

    Any hand operated siphon pump will be able to remove the fluid/antifreeze from the 9000-ECS reservoir. If you want to drain the entire system, you can simply remove the hose connection at the base of the reservoir and allow the fluid to drain out. 

    How helpful was this information?

  • How often should I drain and replace my glycol/water mixture on my 9000-ECS Conditioning unit?
    Amron recommends changing the glycol/water mixture every year.
    How helpful was this information?

  • Can you install more than one 9000-ECS on a chamber?
    There is no problem installing two 9000-ECS units on a chamber. This has been done many times on larger chambers where they require a faster response time for cooling and heating. Please note that each 9000-ECS can support up to three (3) 9100-ICS2’s.
    How helpful was this information?

  • How many 9100-ICS2’s can I install in my chamber if I’m using one 9000-ECS?
    The 9000-ECS can support up to three 9100-ICS2 units.
    How helpful was this information?