Amron Two-Diver Air Control and Communications System with Heating Element REFERENCE ONLY
The Amron AMCOMMAND™ II Two Diver - Air Control/Communications System is a portable, self contained, two diver complete dive system providing both commercial diver air control and superior communications between two commercial divers and topside personnel.
***REFERENCE ONLY***
High Pressure Side:
Low Pressure Side:
Hardwire Communications:
Pneumo (Depth Monitoring) System:
Heating Element Option:
AMCOMMAND™ II 2-Diver Air Control System with Heating Element - P/N: 8225-HP-H Includes:
Air Control Specifications:
Hardwire Diver Communications:
Panel Specs:
Specifications:
WARNING: DO NOT USE THE AMRON OBS-8225-HP-H FOR THE FOLLOWING:
|
***REFERENCE ONLY***
The Amron AMCOMMAND™ II Two Diver - Air Control/Communications System is a portable, self contained, two diver complete commercial dive system. This air control system provides all of the operations necessary to monitor and control the commercial diving operation. It is a central control point for the supply of breathing air to the commercial divers, monitors the commercial divers' depth, provides an audio alarm if the commercial divers' air pressure falls below a preset limit, and provides superior hardwire diver communications for two commercial divers and topside personnel.
Easy set-up with high pressure air sources or low pressure air, which greatly extends search and rescue diving capabilities. To use the Amcommand II with 4500 PSIG inlet air supply, simply change the yoke assembly with the Model SAA5300, 300 BAR DIN adapter. The hardwire diver communications system can be both full duplex or simplex. The optional Wireless Tender provides the tender with freedom around the dive site while staying in constant communication with the divers. The case is extremely strong and durable, constructed of pressure fused fiberglass that provides a convenient, compact, rugged and professional system designed for years of reliable operation.
FAQ's
70 lbs (31.75 kg)
Yes, but we do not recommend using oxygen enriched breathing mixures above 40%.
Yes, you will need a cable that allows you to connect the communicator to your computer. You will also need audio recording software installed on your computer. On the back of the communicator there is a single RCA Phono jack (color-coded black) that provides a transformer isolated of both the diver and tender communications. It is designed to drive the standard line-level inputs of audio or video recorders with input impedances as low as 600 Ohms.
No, the high pressure regulators are not independently routed and they share a common air manifold.
Yes, an inspection report is included with each unit. The pneumo gauges come with a calibration certificate and sticker.
The gauges supplied with this unit are dual scale in both feet and meters of seawater.
If the unit is plugged into a live outlet and turning on the switch does not cause the AC POWER LED to light up, then the fuse(s) are probably blown. Unplug the unit from the outlet, remove the fuses and check continuity with a multimeter. Replace any fuse that does not show continuity.
When operating your Amron Diver Communicator on AC, it is critical to use a Ground Fault Circuit Interrupter (GFCI) or isolation transformer for tender and diver safety. Surges and spikes are common on AC lines found on ships, generated locally, or at the end of long extension cable runs and can exceed 1kVolt. Such surges and spikes can cause the fuse to blow on the amplifier card assembly. The power supply is designed so that such a failure will be isolated and will not cause a safety issue to the tender or divers. It is strongly advised that your Amron Diver Communicator be operated on an AC circuit with a high quality surge arrester or an AC isolation transformer.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
-
Amron Low Air Pressure Alarm System - Trip Point 22.5 to 112 PSISKU: 8206-DSHIP NOWwas $564.00 Sale Price $525.00