Features:

  • Two Modes of Operation - 2-Wire Mode and/or 4-Wire Mode
  • Separate volume controls for operator and each lock
  • Separate on/off controls for each lock
  • External 12 VDC connection

Specifications:

  • Power: 115/230 VAC, 50-60Hz
  • Audio Output Power: 20 Watts
  • Back-up Power: Rechargeable 12 VDC Slide Terminal Gel Cell
  • Rear Panel Connection: MS 14 Pin Male with Mating Connector
  • Entertainment Input: 2 RCA jacks for (2820A-4003E only) audio input, signal is mixed internally for a stereo input/monaural output
  • Dimensions: 8.0 in. H x 10.1in. W x 7.5 in. D (20.3 cm x 25.7 cm x 19.1 cm)
  • Weight: 14 lbs (6.4 kg)

Amcom ™ II Double Lock Chamber Communicator - P/N: 2820A-4003 Includes:

  • (1) Hand-Held Push-to-Talk Microphone - P/N: 2405-28
  • (1) 12 VDC Slide Terminal Gel-Cell Rechargeable Battery - P/N: 2890-05 - Expected life: 20 hrs
  • (1) MS Connector – 14 Pin Female - P/N: MS-3106A-20-27S
  • (1) MS Cable Clamp 20/22 Shell - P/N: MS-3057-12A
  • (1) Power Cord - P/N: P-2392
  • (1) User Manual

Tech Note:

All communicators will transfer topside noise to the diver when using the radio speaker only. To eliminate background noise and achieve clear concise communications, use a Push-to-Talk microphone, headset, or a Remote Walk-and-Talk with a headset.

2 and 3 Year Extended Warranties are available for this product. Please refer to the Attachments tab for further information on the warranty program.

DISCLAIMER NOTICE: Amron's chamber communications are designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Misuse of our chamber communicator products in high-concentration Oxygen environments may result in serious injury and/or death.

This item number has been replaced by 2820A-02

 

The Amcom ™ II 2820A-4003 Double Lock Chamber Communicator is a fully featured hard-wire, two-lock communicator system. The Amcom ™ II has independent volume controls (operator, inner lock, and outer lock), as well as separate on/off controls for each lock.

DISCLAIMER NOTICE: Amron's chamber communications are designed to be used in air chambers where oxygen concentrations remain below 23.5%. Our communications products (including communicators, speakers, entertainment systems, and other communications accessory items) are NOT designed for oxygen service, are not intrinsically safe, and do not meet the criteria given in NFPA-99, Chapter 20 and other applicable definitions. Misuse of our chamber communicator products in high-concentration Oxygen environments may result in serious injury and/or death.

FAQ's
How do I replace rechargeable the battery on my 2820A-4003 communicator?

Battery Replacement Procedure for Models 2820A-4003 & 2820A-4003E

1. Remove 4 ea. screws that attach 2820A-4003E to console.

2. Slide unit out of console cut-out and disconnect Power cord, MS connector & entertainment connector located on rear of unit.

3. Remove 2 ea. screws located on both sides of unit, total 4 ea. screws.

4. Remove Battery box chassis from card box.

5. Disconnect color coded battery slide terminals from battery.

6. Remove old battery.

7. Install new battery.

8. Install color coded battery slide terminals on battery making sure that red wire connects to red (+) terminal on battery and black wire connects to the black (-) terminal on battery.

9. Install chassis to card box being careful not to pinch or damage any wires.

10. Install 2 ea. screws located on both sides of unit, total 4 ea. screws.

11. Slide unit in console cut-out and connect power cord, MS connector & entertainment connector located on rear of unit.

12. Install 4 ea. screws that attach 2820-4003E to console.

13. Turn unit on and check for proper operation.

How do I install a new microphone in my Amcom II or III Communicator?
Please refer to the Panel Microphone Installation instructions located in the attachments tab.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!