Optional diverter (P/N: 9507-D) available for purchase along with with this sensor
Output: 8-13 mV in air at 25°C/77°F, sea level
Electrical Connector:
Typical mating plug switchcraft: .141 in. miniature phone plugs - screw or clamp-lug terminal
Polarity: Tip = negative (–), Sleeve = positive (+)
Range: 0-100% Oxygen
Accuracy: ±1% of full scale at constant temperature and pressure (0-1 atm) when calibrated with 100% oxygen
Sensor Type: Electrochemical
External Thread Size: M 16X1
Expected Sensor Life: 36 months in air at 25°C/77°F and 50% rh
Response Time: <6 seconds for 90% of final value
Operating Temperature: 32-104°F (0-40°C)
Storage Temperature: 32-122°F (0-50°C)
Humidity: 0-99% rh (non-condensing)
Weight: 1.1 oz (31 g)
Warranty: Warranty period begins on the date of manufacture
0 – 12 Months Free Replacement
13 – 18 Months 50% Off Replacement
19 – 24 Months 25% Off Replacement
WARNING: Never expose gas sensors to pressure, or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death.
Application: For surface/above-water diving cylinder verification applications; not intended for underwater use.
Fits the Nuvair Pro O2 Alarm Panel Mount (P/N: 9612-B-R) and the DE-OX ZIP PRO (P/N: 9631).
Optional diverter (P/N: DIVERTERS) available for purchase with this sensor (P/N: 9507-D).
Output: 8-13 mV in air at 25°C/77°F, sea level
Electrical Connector:
Typical mating plug switchcraft: .141 in. miniature phone plugs - screw or clamp-lug terminal
Polarity: Tip = negative (–), Sleeve = positive (+)
Range: 0-100% Oxygen
Accuracy: ±1% of full scale at constant temperature and pressure (0-1 atm) when calibrated with 100% oxygen
Sensor Type: Electrochemical
External Thread Size: M 16X1
Expected Sensor Life: 36 months in air at 25°C/77°F and 50% rh
Response Time: <6 seconds for 90% of final value
Operating Temperature: 32-104°F (0-40°C)
Storage Temperature: 32-122°F (0-50°C)
Humidity: 0-99% rh (non-condensing)
Weight: 1.1 oz (31 g)
Warranty: Warranty period begins on the date of manufacture
0 – 12 Months Free Replacement
13 – 18 Months 50% Off Replacement
19 – 24 Months 25% Off Replacement
WARNING: Never expose gas sensors to pressure, or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death.
The Nuvair 9507 replacement oxygen sensor is intended for use with the Nuvair Pro O2 Alarm Panel Mount (P/N: 9612-B-R) and the DE-OX ZIP PRO (P/N: 9631) oxygen analyzer. Optional diverter available for purchase (SKU: 9507-D).