Not a valid Time
This is a required field.

Nuvair Oxygen (O2) Sensor Replacement for Pro Oxygen (O2) Analyzers

SKU
NUV-9507M
$122.60
Eligible for Free Shipping Over $125
REPL O2 SENSOR W/MOLEX 8-13MV FOR PRO O2 ALARM

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
  • CA PROP65
    Warning: Cancer and Reproductive Harm www.p65warnings.ca.gov
  • MSDS
    Safety Data Sheet available online or by request.
More Information

Oxygen (O2) Sensor Replacement for Pro Oxygen (O2) Analyzers NUV-9507M is a replacement electrochemical oxygen sensor for gas analyzers. Fits the following analyzers:

Specifications:

  • Application: For surface/above-water diving cylinder verification applications; not intended for underwater use.
  • Output: 8-13 mV in air at 25°C/77°F, sea level.
  • Electrical Connector: Mating plug: Molex (PN 22-01-3037 or 22-01-2037)
  • Range: ±1% of full scale at constant temperature and pressure (0-1 atm) when calibrated with 100% oxygen.
  • Sensor Type: Electrochemical
  • Expected Sensor Life: 
    • 12 Months – 100% Parts and Labor
    • 13-18 Months – 50% Sensor Only
    • 19 – 24 Months – 25% Sensor Only
  • Response Time: <6 seconds for 90% of final value.
  • Operating Temperature: 32-104°F (0-40°C)
  • Storage Temperature: 32-122°F (0-50°C)
  • Humidity: 0-99% rh (non-condensing)
  • Weight: 1.2 oz. (32 g)

*WARNING: Never expose gas sensors to pressure or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death.

Nuvair's Oxygen (O2) Sensor Replacement for Pro Oxygen (O2) Analyzers NUV-9507M is a replacement electrochemical oxygen sensor for gas analyzers.
ATTACHMENTS
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone