Not a valid Time
This is a required field.

Nuvair Pro Oxygen (O2) Alarm Analyzer Handheld Series

SHIP NOW
Only %1 left
SKU
9611 Series
As low as $533.00
Eligible for Free Shipping Over $125
The handheld Nuvair Pro O2 Alarm Analyzer is easy to operate and rugged. Users can set two audible/visible alarms for high and low oxygen (O2) percentages. When the alarm sounds, the analog output can activate an optional relay that automatically shuts down compressors, sounds an alarm, or activates a back-up system. Three power and two module options.

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
  • CA PROP65
    Warning: Cancer and Reproductive Harm www.p65warnings.ca.gov
  • MSDS
    Safety Data Sheet available online or by request.
Selection Tool
More Information

Features:

  • Completely sealed, water resistant housing.
  • Specifically designed to test breathing gases.
  • Audible alarm sounds when user-defined low or high oxygen percentage is reached.
  • Analog output can activate optional relay to automatically shutdown compressor when alarm activates.
  • Fast response, thermally compensated sensor.
  • Automatic/easy calibration.
  • Low battery warning indicator.
  • User-replaceable battery and sensor.
  • On/off switch.

Specifications:

  • Display Accuracy: ±1%
  • Sensor Type: Electrochemical
  • Expected Cell Life: 36 months in air at 77°F/25°C and 50% rh
  • Output for External Devices: 4 - 20 mA analog
  • Range: 0 - 100% oxygen
  • Response Time: <6 seconds for 90% of final value
  • Operating Temperature: 32°F/0°C – 104°F/40°C
  • Storage Temperature: 32°F/0°C – 122°F/50°C
  • Operating Humidity: Up to 100% rh
  • Dimensions: 4 -1/8 in. L x 2 -1/2 in. W x 1 -3/4 in. H 
  • Replacement Sensor: Oxygen Sensor Replacement 9506

Power Options:

  • 9 Volt Battery
  • Rechargeable Lithium Battery
  • 110/220V Wall Plug-In (International) Power
  • 110/220V Wall Plug-In + FAILSAFE Module
  • 110/220V Wall Plug-In + SMART START Module

*WARNING: Never expose gas sensors to pressure or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death.

Features
  • Easy to operate, extremely accurate and stable.
  • Preferred by commercial, military, technical and advanced recreational divers using nitrox and non-divers who require a simple oxygen analysis of compressed gas or contained spaces.
  • Audible and visual alarms for low and high oxygen content can be set by the user.
  • If the alarm sounds, the analog output can activate an optional relay that shuts down compressors automatically, sounds a remote alarm, or activates an emergency backup system.
  • Water- and impact-resistant case is designed for everyday use in the marine environment.
  • To change the battery or sensor, simply remove four screws to access user-changeable components.
  • All Nuvair Pro O2 units are built and tested in-house, and are ready to use upon receipt.
  • Audible alarm sounds when user-defined low or high O2 percentage is reached.
  • 4-20 mA analog output for external devices
  • On/Off switch
  • Low battery warning indicator
  • Easy and automatic calibration
  • User-replaceable battery and sensor
  • Fast response, thermally compensated sensor
  • Completely sealed, water-resistant housing
  • Specifically designed to test breathing gases

 

Specifications
  • Display Accuracy: ±1%
  • Sensor Type: Electrochemical
  • Expected Cell Life: 36 month in air at 25°C (77°F) and 50% rh
  • Range: 0–100% oxygen
  • Response Time: <6 seconds for 90% of final value
  • Operating Temperature: 32–104°F (0–40°C)
  • Storage Temperature: 32–122°F (0–50°C)
  • Operating Humidity: Up to 100% rh
  • Power Options:
    • 9-Volt Battery
    • Rechargeable Lithium Battery
    • 110/220V Wall Plug-In (International) Power
    • 110/220V Wall Plug-In + FAILSAFE Module
    • 110/220V Wall Plug-In + SMART START Module
  • Dimensions (L x W x H): 4-1/8 × 2-1/2 × 1-3/4 in. (10.5 × 6.2 × 4.4 cm)
  • Replacement Sensor: 9507M

 

WARNING: Never expose gas sensors to pressure, or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death.

Nuvair's Pro Oxygen (O2) Alarm Analyzer Handheld Series - NUV-9611 is an easy to operate, extremely accurate and stable, the Nuvair Pro Oxygen (O2) Alarm Analyzer Handheld Series - NUV-9611 is preferred by commercial, military, technical and advanced recreational divers using nitrox and non-divers who require a simple oxygen analysis of compressed gas or contained spaces. Audible and visual alarms for low and high oxygen content can be set by the user. If the alarm sounds, the analog output can activate an optional relay that shuts down compressors automatically, sounds a remote alarm, or activates an emergency backup system.

The handheld Nuvair Pro O2 Alarm Analyzer is easy to operate and rugged. Users can set two audible/visible alarms for high and low oxygen (O2) percentages. When the alarm sounds, the analog output can activate an optional relay that automatically shuts down compressors, sounds an alarm, or activates a back-up system. Three power and two module options.

 

Easy to operate, extremely accurate and stable, the handheld Nuvair Pro O2 Alarm Analyzer is preferred by commercial, military, technical and advanced recreational divers using nitrox and non-divers who require a simple oxygen analysis of compressed gas or contained spaces. Audible and visual alarms for low and high oxygen content can be set by the user. If the alarm sounds, the analog output can activate an optional relay that shuts down compressors automatically, sounds a remote alarm, or activates an emergency back-up system. Price varies according to power options.

 

This water- and impact-resistant case is designed for everyday use in the marine environment. To change the battery or sensor, simply remove four screws to access user-changeable components. All Nuvair Pro O2 units are built and tested in-house, and are ready to use upon receipt.

 

WARNING: Never expose gas sensors to pressure, or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death.

ATTACHMENTS
file-icon
file-icon
file-icon
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!