×

:

Not a valid Time
This is a required field.

Hans Rudolph 7400 Series V Mask

Only %1 left
SKU
66917X-VMASK

Hans Rudolph 7400 Series V Mask

  • The Hans Rudolph 7400 series Vmask face piece is designed for use with the Hans Rudolph Two-Way Non-Rebreathing Valves (NRBV) and other mask adapters.
More Information

Product Features:

  • Five Sizes of Face Pieces to cover a wide range of patient sizes.
  • Face Piece with Facial Sealing Flange is a single piece mask, made of translucent blue soft Silicone Rubber.
  • Sensa Seal™ accessory add-on aids sealing in the nose area. (Not included)
  • Anatomically Contoured Face Mask design for a leak free comfortable fit and integrated Chin Cup for stability.
  • Reusable mask face pieces; steam autoclaveable, cold chemical, pasteurization and dishwasher safe.
  • Reusable swivel ports validated for sterilization via steam autoclaving or high level disinfection via cold chemicals or pasteurization for re-use.

Specifications:

  • Face Piece: Silicone Rubber Translucent Blue
  • Sensa Seal: Not included (Silicon Rubber Clear)

Intended Use:

  • The Hans Rudolph 7400 series Vmask™ face piece is designed for use with the Hans Rudolph Two-Way Non-Rebreathing Valves (NRBV) and other mask adapters.
  • Designed for respiratory circuits with spontaneously breathing patients where the application requires a valve to separate the patient’s inspiratory and
    expiratory flows or a special connector to mate directly to a respiratory flow meter or other device.
  • The typical mouthpiece and nose clip is replaced by this face mask assembly and headgear.
  • The masks and swivels are supplied clean, non sterile.
  • This application is for HBOT
  • These mask and swivels are classified as reusable and can be high level disinfected.

Environment of Use:

  • This mask series is for use in hospitals and other clinical settings by individuals that have at least minimal instructions or training on the use of the mask as well as the device to which the mask are intended to connect.

Mask Service Life:

  • The Mask is expected to stay in service for minimum of 25 disinfection or sterilization cycles or 6 months of use under normal conditions, whichever occurs first. 

Operational conditions for use:

  • Temperature range: 5-40 C
  • Humidity range: 0-95% RH

Cleaning and Disinfection:

  • For cleaning and disinfection care be sure you fully comprehend our cleaning Data Sheet 691195.

Cautions:

  • Federal Law restricts this device to sale by or on the order of a physician.
  • Patients with facial hair, especially beards, may experience mask leakage which may require shaving the hair.
  • Do not use these valves in a life support system such as a ventilator circuit.

Order Numbers for 7400 V™ Series Face Pieces & Headgears:

Ordering

P/N

Face Piece Only
Silicone Rubber No Adaptor
or Headgear Included

Ordering

P/N

Quick-Release Headgear
Black Mesh with Pull String & Stretch
Velcro Straps & Clips

Ordering

P/N

Standard Headgear
Black Mesh with Stretch
Velcro Straps & Clips

Ordering

P/N

Sensa Seal

Silicone rubber sealing flange accessory for
additional sealing in the nose area of the mask

669174 Petite (P)         669164 Large (L)
669173 Extra Small (XS)         669163 Medium (M)
669172 Small (S)         669162 Small (S)
669171 Medium (M) 201419 Small (S) 201079 Small (S) 669161 Extra Small (XS)
669170 Large (L) 201418 Large (L) 200525 Large (L) 669160 Petite (P)

 

Mask Face Piece Size (For more information see photos)

Characteristic Petite (P) Extra Small (XS) Small (S) Medium (M) Large (L)
A (inches) 4.6 4.8 5.2 5.5 5.9
B (inches) 2.5 2.7 2.8 3.1 3.4
C (inches) 3.9 3.9 4.0 4.2 4.2
Deadspace (ml) 53 62 73 97 114
Weight (gm) 95 101 108 117 127

Hans Rudolph 7400 Series V Mask

  • The Hans Rudolph 7400 series Vmask face piece is designed for use with the Hans Rudolph Two-Way Non-Rebreathing Valves (NRBV) and other mask adapters.
  • Designed for respiratory circuits with spontaneously breathing patients where the application requires a valve to separate the patient’s inspiratory and expiratory flows or a special connector to mate directly to a respiratory flow meter or other device.
  • The typical mouthpiece and nose clip is replaced by this face mask assembly and headgear.
  • The masks and valves are supplied clean, non sterile.
  • Typical applications are for pulmonary function testing, exercise testing and respiratory research.
  • These mask valves are classified as reusable and can be high level disinfected.
ATTACHMENTS
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!