Not a valid Time
This is a required field.

Cygnus 6+ PRO Ultrasonic Thickness Meter & Probe

SKU
CYG-050-6500/5+PROBE

From $3,392.02

To $3,922.95

Add to Wish List

Restrictions / Notifications

  • No Free Shipping
    This item does not qualify for free shipping.
  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
Cygnus 6+ PRO Ultrasonic Thickness Meter (No Probe)
Cygnus 6+ PRO Ultrasonic Thickness Meter (No Probe)   + $3,392.02
SKU: CYG-050-6500/5
Cygnus 004-9500 | S2C Single 2.25 MHz 13 mm BNC
SKU: CYG-004-9500
Cygnus 6+ PRO Ultrasonic Thickness Meter & Probe
Cygnus 6+ PRO Ultrasonic Thickness Meter & Probe

$3,392.02

More Information
Features
  • Multiple-Echo mode for accurate, through-coat measurements as specified by classification societies.
  • Echo-Echo and Single-Echo modes for heavily corroded metals with thin (or no) coatings.
  • Temperature compensation
  • Deep coat function ignores coatings up to 0.8 in. thick.
  • Manual and automatic gain control
  • Min/max measurement limit functions with visual and vibrate alert.
  • Uses both single and twin crystal transducers.
  • One and two point calibration.
  • Freeze function
  • Bluetooth™ for data transfer.
  • Large front LCD display and an end-mounted LCD display with grayscale setting for bright sunlight.
  • Safe operation in explosive atmospheres: Class 1, Division 2, Group D locations only, as defined in NFPA 70, Article 500
  • Water and dust tight IP67 housing.
  • Shock and impact proof to US MIL STD 810G. 

 

High Temperature Measurement
  • Using the T5B-MAUH high temperature transducer, measurements can be taken on hot surfaces of up to 572°F.

  • No cooling period is required – which can reduce inspection time and facilitate more effective measurement.

  • Optional upgrade to braided cable.

 

Comprehensive Data Logging
  • Linear, 2D grid and template data recording options
  • 16 grid patterns available.
  • ‘Radial points’ can be added to any measurement to further investigate an area of interest or heavy corrosion.
  • Auto-log feature
  • Saves measurements and corresponding wave forms / A-scans.
  • Eight user-defined text comments to attach to any measurement point.
  • Records stored on an SD card.
  • Dedicated CygLink software used to transfer and manage data.

 

Three Versatile Measuring Modes
  • Multiple-Echo mode uses three error checked back wall echoes to provide the most reliable and accurate remaining thickness measurements possible, with no need to remove coatings up to 0.8 in. thick.
  • Single-Echo mode is ideal for measuring uncoated metals with heavy front and/or back-wall corrosion. Also effective on a range of cast metals, plastics and composites.
  • Echo-Echo mode works best for measuring heavily corroded metals through thin coatings of up to 0.04 in. thick, ideal for measuring painted metals with heavy back wall corrosion.

 

CygLink Computer Software
  • CygLink is a Windows® based application used to both transfer and manage data logged records, their corresponding A-scans as well as measurement comments and material velocity tables. The program can generate PDF reports to present to a client and will also export data to Excel. Cyglink also displays A‑scans, allowing for after-the-event and off-site analysis of logged measurements.
  • The latest version of CygLink software is available to download on the Cygnus website.

 

Measurement Stability Indicator (MSI™)
  • Exclusive to Cygnus, MSI™ ensures stable and therefore reliable measurements are displayed in Echo‑Echo and Single-Echo modes.

 

Specifications
  • Measuring Modes:
    • Multiple-Echo using 3 echoes to ignore coatings up to 0.8 in. thick
    • Echo-Echo using 2 echoes to ignore coatings up to 0.04 in. thick
    • Single-Echo using 1 echo
  • Materials: Velocities from 0.0390 – 0.3543 in/us
  • Accuracy
    • ±0.002 in. – in Multiple-Echo measurement mode, when calibrated and measuring the same material as calibrated on
      ±0.004 in. – or 0.1% of thickness measurement whichever is the greatest – in Single-Echo & Echo-Echo measurement modes, when calibrated and measuring the same material as calibrated on
  • Resolution:
    • Multiple-Echo mode – 0.005 in. or 0.002 in.
    • Single-Echo and Echo-Echo modes – 0.005 in. or 0.001 in.
  • Transducer Options: Single crystal transducers, twin crystal transducers, and high temperature transducer
  • Measurement Range in Steel: 0.031 – 10 in. depending on selected transducer and configuration, material and temperature
  • Connector: 2 x Lemo 00
  • Power: 3 x AA / R6 batteries
  • Battery Life: Approx. 10 hours continuous measurement
  • Electronics: Dual channel pulser
  • Display: 
    • Front LCD 2.4 in. QVGA: 47 x 37 mm
    • End-mounted LCD: 25.58 x 6.38 mm
  • Size: 3.3 x 5.1 x 1.4 in.
  • Weight: 10.5 oz. (incl. batteries)
  • Operating Temp.: 14°F to 122°F
  • Data Logging:
    • 5,000 measurements and A-scans per record
    • Max number records: 100 (soft limit)
  • Computer Software:
    • CygLink allows remote logging and viewing of A-scan graphs
    • Survey and report generation to PDF file
    • Graphic analysis of data and statistical calculations
  • Environmental Rating: 
    • IP67
    • Safe operation in Explosive Atmospheres: Class I, Division 2, Group D Locations only, as defined in the National Fire Protection Association Code (NFPA 70), Article 500. Tested using MIL-STD-810G, Method 511.5, Procedure I
    • MIL STD 810G Method 501.6 (high temp +55°C)
    • MIL STD 810G Method 502.6 (low temp -20°C)
    • MIL STD 810G Method 507.6 (humidity 95%)
    • MIL STD 810G Method 512.6 (immersion 1 meter for 30 mins)
  • Shock and Impact:
    • MIL STD 810G Method 514.7 (vibration)
    • MIL STD 810G Method 516.7 (shock 20g)
    • MIL STD 810G Method 516.7 (transit drop 1.22 m)
  • Standards: Designed for EN 15317
  • Compliance: CE, UKCA, RoHS
  • Warranty: 3 years on gauge and 6 months on transducer 

 

Basic Gauge Kit
  • Cygnus 6+ gauge fitted with hand strap
  • Operating manual
  • Neck strap
  • Accessory pouch, containing; 3 x AA batteries, blue couplant gel
  • USB memory stick with CygLink installer
  • USB lead

 

Kit supplied with Single Element Transducer
  • Ultrasonic transducer
  • Molded transducer cable
  • 1/2 in. (15 mm) steel test block
  • Spare membranes
  • Membrane key
  • Membrane couplant

 

Kit supplied with Twin Element Transducer
  • Ultrasonic transducer
  • Molded transducer cable

 

Variety of Cygnus INOX Transducers
  • Stainless steel SINGLE CRYSTAL transducers, used in multiple-echo mode, include replaceable membranes for long life, require no zeroing and have a high linear accuracy.
  • Stainless steel TWIN CRYSTAL transducers, used in echo-echo and single-echo modes, have improved measurability on extreme back wall corrosion and pitting.
  • Transducers for use with the Cygnus 2+, 4, 4+ and 6+ gauges are fitted with a BNC or Lemo 00 connector.

 

Single Crystal Probes
Twin Crystal Probes

The Cygnus 6+ UT thickness gauge boasts a full suite of features for the demanding professional user, including: A-scan; B-scan; full data recording capability; 3 distinct measuring modes; high temperature transducer and manual gain control.

 

To compliment Cygnus' ultrasonic thickness gauges, Cygnus offers a range of ultrasonic transducers. The performance of any ultrasonic thickness gauge relies heavily on the transducer and its suitability to the material being measured. Therefore, selecting the right transducer is vital. All Cygnus’ transducers are made from stainless steel and have a hard wear face or a wear membrane to protect the transducer.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!