Amron BIBS Mask

Features
450M BIBS Mask - P/N: 450M-01 Includes
Warning: The Amron 450M BIBS Mask was designed and is for use within a hyperbaric chamber only. It is NOT intended for and must NOT be used underwater.
|
Amron International's new 450M BIBS Mask is the perfect combination of performance, durability and comfort. The Amron 450M BIBS Mask was specifically designed and tested to meet the rigorous Norsok U-101:1999 breathing standard. Unlike other BIBS on the market today, Amron's 450M BIBS Mask is built to withstand the extreme conditions found in a saturation diving environment.
The Amron 450M BIBS Mask demand regulator is fully adjustable to allow for easy breathing from surface decompression all the way down to 450 meters pressurized depth. Diver’s comfort was a major consideration so the 450M comes standard with a comfortable oral nasal and a supportive head strap.
For chamber depths over 99 feet of seawater, a secondary vacuum regulator must be installed (see Tescom Regulator Part #: 26-2912-282A). A hull-stop valve should be an integral part of the hyperbaric system; used as a safety device to shut down the vacuum should a pressure loss occur. The vacuum regulator allows the exhaled gases to be carried to the outside of the chamber thereby eliminating oxygen buildup or contamination of the chamber environment.
Features:
- Third Party Tested to Norsok U-101:1999
- Easy Breathing (light inhalation and exhalation resistance, resulting in a low work of breathing)
- Rugged Regulator Housing with Stainless Steel Valve Assemblies
- Tool-less Removal of Demand and Exhaust Valve Assemblies for ease of maintenance and service
- Pneumatically Balanced Demand Regulator with fine tune adjustment
- Pneumatically Balanced Exhaust Regulator with overboard dump, permits minimum ventilation of the chamber
- Vacuum Relief Valve Included
- Gas Router and CO2 Purge Mechanism Attached to the Valves
- Double Diaphragm Design with Removable Diaphragms and locking Diaphragm Covers for proper alignment and compression
- Ultrafit, Hi-Comfort Silicone Oral Nasal, designed to fit most faces and designed to accommodate a microphone option
- Full Head Harness for added comfort during long administration
- Pressure and Collapse tested 10 ft. Hose Assembly with Quick Disconnects included
- For use with Air, Oxygen, or Heliox
- A unique microphone (Part #: 550-0010-01) can be linked to an Amcom ™ series communicator, allowing the person inside the chamber to clearly communicate with people outside the chamber
- Patent No. 8,336,547
- Int. PCT. Pat. No. US2012/066144
450M BIBS Mask - P/N: 450M-01 Includes:
- (1) 10 Foot Hose Assembly - P/N: 540-0004-01
- (1) Oxygen Cleaned Quick Disconnect Socket - Brass - P/N: 59853-00
- (1) Oxygen Cleaned Quick Disconnect Socket - P/N: 18969-00
- (1) 450M BIBS Mask User's Manual - P/N: 450M-UM
- (1) Certificate of Conformance
Warning: The Amron 450M BIBS Mask was designed and is for use within a hyperbaric chamber only. It is NOT intended for and must NOT be used underwater.
Amron International's 450M BIBS Mask is the perfect combination of performance, durability and comfort. The Amron 450M BIBS Mask was specifically designed and tested to meet the rigorous Norsok U-101:1999 breathing standard. Unlike other BIBS on the market today, Amron's 450M BIBS Mask is built to withstand the extreme conditions found in a saturation diving environment.
The Amron 450M BIBS Mask demand regulator is fully adjustable to allow for easy breathing from surface decompression all the way down to 450 meters pressurized depth. Diver’s comfort was a major consideration so the 450M comes standard with a comfortable oral nasal and a supportive head strap.
For chamber depths over 99 feet of seawater, a secondary vacuum regulator must be installed (see Tescom Regulator Part #: 26-2912-282A). A hull-stop valve should be an integral part of the hyperbaric system; used as a safety device to shut down the vacuum should a pressure loss occur. The vacuum regulator allows the exhaled gases to be carried to the outside of the chamber thereby eliminating oxygen buildup or contamination of the chamber environment.
FAQ's
The 450M BIBS mask was designed to be used at depths between 0 to 450 MSW which gives our customers the widest working depth rating available on the market today. The 450M perfoms best from depths between 350 MSW and 450 MSW.
If you plan on using your BIBS system at depths shallower than 350 MSW, we recommend that you purchase the Amron 350M BIBS mask.
Yes.
Yes, you can overhaul the 450M BIBS Mask. The user manual provides factory suggested procedures and instructions for operating, maintaining and servicing the Amron 450M BIBS Mask. Any service or maintenance performed on the 450M breathing system shall be done only by those facilities experienced in or by personnel knowledgeable in oxygen equipment.
The 450M BIBS mask was designed to be used from 0 - 450 MSW depths which gives our customers the widest working depth rating available on the market today. The 450M perfoms best from depths between 350 MSW and 450 MSW.
The Avox Pressur-Vak II BIBS mask system has been commonly used in hyperbaric chambers to depths of up to 100 MSW for many years. Amron is pleased to confirm that the Avox Pressur-Vak II will continue to be readily available from Amron for many years to come.
Yes, both the Amron and Avox BIBS Mask connect to same Hansen quick disconnects. Amron part number 59853-00 for the exhaust quick disconnect and 18969-00 for the oxygen inlet.
Built-in Breathing System
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders