×

:

Not a valid Time
This is a required field.

Amron 8300-HP Air Control and Depth Monitoring System for 3 Divers 1 Regulator and 2 Low Pressure Inputs

SKU
8300-HP
$15,622.00
Eligible for Free Shipping Over $125

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
More Information

Features 

  • One 44-1300 Series Tescom Pressure Reducing Regulators
  • One high pressure and two low pressure air source connections
  • Convenient switching between high pressure or low pressure
  • Low air pressure audio alarm
  • 50 Micron in-line stainless filter on regulator input
  • Check valves on all source inputs
  • Automatic gauge protectors and snubbers protect against over pressurization of precision pneumo gauges

Specifications 

  • Air Control - High Pressure Section
    • Inlet Connection (1): #6 JIC
    • Input Air Pressure Range: 500-5000 PSIG
    • Inlet Valve (2): Source Select
    • Pressure Gauge: 0-6000 PSIG Accuracy ±1.5%
    • Input Air Filter, Inline Pre-regulator: 50 Micron
    • Tescom High Pressure Reducing Regulators: 2 ea.
    • Output Air Pressure Range: 0-300 PSIG
    • Max Air Pressure: 5000 PSIG
  • Air Control - Low Pressure Section
    • Inlet Connection (2): #8 JIC
    • Check Valve: 2 ea.
    • Commercial Diver Outlet Connection: 3 each O2 fittings
    • Commercial Diver Outlet Valve: 3 each
    • Air Pressure Gauge: 3 each 0-400PSIG Accuracy ±1.5%
    • Over-pressure Relief Valve: Set pressure 285PSIG
  • Depth Monitoring Pneumo
    • Pneumo Gauge: 3 ea. 6 in. Dual Scale
    • Range Dual Scale: 0-250FSW / 0-76MSW
    • Accuracy: 0.25% of Full Scale with 1ft. Divisions
    • Pneumo Valves (7): Regulating Valve KEL-F Seat
    • Outlet Connection (3): O2 fitting, brass
    • Low Air Pressure Alarm: Pressure Range, 22.5-125 PSIG, Factory Set at 100 PSIG
  • Panel Construction
    • Panel Material: Aluminum, Stainless Steel
    • Powder Coating: Black textured semi-gloss polyester
    • Graphics: Yellow and White silkscreened
  • Case Dimensions
    • Lid Closed: 25 in. W x 20 in. D x 15 in. H
    • Lid Open: 25 in. W x 20 in. D x 29 in. H
    • Weight: 95 lbs. (approx) 

WARNING: DO NOT USE THE AMRON 8300-HP FOR THE FOLLOWING:

  • Mixed gas diving operations with an oxygen level greater than 25%.
  • Oxygen or oxygen enriched breathing mixtures above 25%.
Features

  • One 44-1300 series Tescom pressure reducing regulators
  • One high pressure and two low pressure air source connections
  • Convenient switching between high pressure or low pressure.
  • Low air pressure audio alarm.
  • 50 micron in-line stainless filter on regulator input.
  • Check valves on all source inputs.
  • Automatic gauge protectors and snubbers protect against over pressurization of precision pneumo gauges.

 


Specifications

Air Control
High Pressure
  • Inlet Connection (1): #6 JIC
  • Input Air Pressure Range: 500-5000 PSIG
  • Inlet Valve (2): Source select
  • Pressure Gauge: 0-6000 PSIG accuracy ±1.5%
  • Input Air Filter, Inline Pre-regulator: 50 micron
  • Tescom High Pressure Reducing Regulators: 2 ea.
  • Output Air Pressure Range: 0-300 PSIG
  • Max Air Pressure: 5000 PSIG

 

Low Pressure
  • Inlet Connection (2): #8 JIC
  • Check Valve: 2 ea.
  • Commercial Diver Outlet Connection: 3 each O2 fittings
  • Commercial Diver Outlet Valve: 3 each
  • Air Pressure Gauge: 3 each 0-400 PSIG accuracy ±1.5%
  • Over-pressure Relief Valve: Set pressure 285 PSIG

 

Depth Monitoring Pneumo
  • Pneumo Gauge: 3 ea. 6 in. dual scale
  • Range Dual Scale: 0-250 FSW / 0-76 MSW
  • Accuracy: 0.25% of full scale with 1 ft. divisions
  • Pneumo Valves (7): Regulating valve KEL-F seat
  • Outlet Connection (3): O2 fitting, brass
  • Low Air Pressure Alarm: Pressure range, 22.5-125 PSIG, factory set at 100 PSIG

 

Panel
  • Panel Material: Aluminum, stainless steel
  • Powder Coating: Black textured semi-gloss polyester
  • Graphics: Yellow and white silkscreened

 

Case
  • Lid Closed: 25 in. W x 20 in. D x 15 in. H
  • Lid Open: 25 in. W x 20 in. D x 29 in. H
  • Weight: 95 lb. (approx) 

 

Warning: Do Not Use the Amron 8300-HP for the following
  • Mixed gas diving operations with an oxygen level greater than 25%.
  • Oxygen or oxygen enriched breathing mixtures above 25%.

The Amron Model 8300 Portable 3-Diver Air Control and Depth Monitoring System is a portable, self-contained three commercial diver high and low pressure air control and depth monitoring (pneumo) system for surface supplied commercial diving operations. The Amron Model 8300 Portable 3-Diver Air Control and Depth Monitoring System is designed to provide a central control point for the supply of breathing air to three commercial divers and monitor their depth. The Amron Model 8300 Portable 3-Diver Air Control and Depth Monitoring System is housed in a durable, pressure-fused fiberglass case that provides a convenient, compact, rugged and professional system.

 

Depth Monitoring with cross connect capability. Automatic pressure gauge protectors in addition to pressure gauge snubbers protect against over-pressurization. The pneumo panel has the ability to cross-check all depth gauges. The commercial divers' pneumo connection is an O2 type fitting, pneumo valves are regulating type. Pneumo gauges are 6 in. high precision 0.25% of full-scale accuracy, dual scale 0-250 FSW/0-76 MSW with 1 ft. increments.

 

Low air pressure alarm module supplies a loud audio signal to alert the operator when a commercial diver's air pressure falls below a pre-set limit of 100 PSIG.

 

The optional heating cable is 24 ft. long and is wrapped around the HP input and regulator section located on the backside of the manifold panel. The standard plug connect 120 VAC heater is located on the front panel for ease of use. As an added safety feature, a GFCI inline cord set is supplied. The lower case is insulated with closed cell foam to help protect against severe weather conditions.

 

WARNING: DO NOT USE THE AMRON 8300-HP FOR THE FOLLOWING

  • Mixed gas diving operations with an oxygen level greater than 25%.
  • Oxygen or oxygen enriched breathing mixtures above 25%.

The Amron model 8300-HP Air Control and Depth Monitoring System is a portable, self-contained, 3-diver, high and low pressure input air control with depth monitoring for supporting commercial diving operations. The 8300-HP provides a central control point for supplying breathing air to three commercial divers while monitoring their depth. The air control is housed in a compact, durable, pressure-fused fiberglass case.

 

The 8300-HP provides capabilities for depth monitoring, automatic pressure gauge protectors, and pressure gauge snubbers that protect against over-pressurization. The depth monitoring pneumo panel has the ability to cross-connect and cross-check all depth gauges. The pneumo hose connection is an O2 type fitting. Pneumo valves are regulating type valves. Pneumo gauges are 6 in., high precision, 0.25% of full-scale accuracy, with dual scales (0-250 FSW/0-76 MSW in 1 ft. increments).

 

The low air pressure alarm emits a loud, 2.9 kHz audio signal to alert the operator when a diver's air pressure falls below a pre-set limit of 100 psig.

 

An optionally configured model 8300-HP air control with heating cable provides all of the features above but includes an optional heating cable that’s wrapped internally around the HP input and regulator section located on the backside of the manifold panel. The heating option allows for diving in air temperatures below 45 degrees Fahrenheit. The heating cable is connected to 120 VAC using a NEMA 5-15P 3-prong plug and a GFCI in-line device (included). The lower case is insulated with closed cell foam to retain heat inside the case and protect against severe weather conditions.

 

WARNING: DO NOT USE THE AMRON 8300-HP FOR THE FOLLOWING
  • Mixed gas diving operations with an oxygen level greater than 25%.
  • Oxygen or oxygen enriched breathing mixtures above 25%.
FAQ's
Can I have the low pressure inlet fitting changed from JIC #8 to a JIC #10?
Yes, but there will be an added cost for additional parts and labor. Please contact us if you are interested in receiving a price quote for the change.
Can I have the high pressure inlet fitting changed from a JIC #6 to a JIC #4?
No, this is not recommended because the JIC #4 fitting will not support 3 divers when the supply pressure drops between 500-1000 psi, especially if the diver is working deep.
Can I have the low pressure diver outlet fittings from Oxygen to JIC #6?
Yes, but there will be an added cost for the additional parts and labor. Please contact us if you are interested in receiving a price quote for the change.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!