Not a valid Time
This is a required field.

Amron Explosion Proof Chamber Communicator

SKU
2810E-ATEX

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
  • Contact us for a quote: Call (877) 462-6700 or email sales@amronintl.com.
More Information
Features
  • State-of-the-art electronics.
  • Operates in 2-wire communication mode only.
  • Single volume control for the up-link (operator) and another volume control for the down-link (chamber).
  • Housed in a rugged IEC Class 1, Zone 2-rated cast aluminum enclosure.
  • Comes standard with an 8Ω MEDC ATEX-rated speaker.
  • Speaker cable, power/chamber/light cable, and all connectors are also ATEX rated.
  • No back-up battery.
 
Electrical Specifications
  • Input Impedance (Microphone Input): 300 Ω
  • Frequency Response: 300 - 4000 Hz
  • Common Mode Rejection (minimum): 40 dB
  • Current Drain - Maximum Full Volume: 1 amp
    • Typical Quiescent: 50-130 mAmps
  • Minimum Load Impedance: 4Ω
  • Nominal Power Supply Voltage: 15 VDC
  • Operational Supply Voltage: 13VDC ‑ 18 VDC
  • Sensitivity (Input): 1.8 mVRMS
  • Maximum Output Power (4Ω Load, 14 Vdc): 10 watts
 
MECHANICAL SPECIFICATIONS
  • Enclosure: Aluminum
  • Width: 13.0 in. (33.0 cm)
  • Depth: 9.0 in. (22.9 cm)
  • Height with Speaker: 20.5 in. (52.0 cm)
  • Weight: 49 lbs. (22.23 kg)
Features
  • ATEX-rated, explosion-proof, dual-lock chamber communicator.
  • Separate volume controls for the operator and chamber.
  • Push-to-talk button for operator communication to chamber occupants.
  • Operates in 2-wire communication mode only.
  • The “always on” communicator speaker continuously monitors chamber audio.
  • ATEX-rated speaker also functions as the operator microphone.
  • Separate power, switching, and wiring for controlling a chamber light.
  • Rugged IEC Class 1, Zone 2-rated, air-tight, cast aluminum enclosure.
  • Pre-wired cable with labeled wires.
  • No back-up battery.

 

Electrical Specifications
  • Input Impedance (Microphone Input): 300 Ω
  • Frequency Response: 300 - 4000 Hz
  • Common Mode Rejection (Minimum): 40 dB
  • Current Drain - Maximum Volume: 1 A
  • Typical Quiescent: 50-130 mA
  • Minimum Load Impedance: 4Ω
  • Nominal Power Supply Voltage: 15 Vdc
  • Operational Supply Voltage: 13‑18 Vdc
  • Sensitivity (Input): 1.8 mVRMS
  • Maximum Output Power (4Ω Load, 14 Vdc): 10 W

 

Mechanical Specifications
  • Enclosure: Aluminum, IEC Class 1, Zone 2-Rated
  • Width: 13.0 in. (33.0 cm)
  • Depth: 9.0 in. (22.9 cm)
  • Height with Speaker: 20.5 in. (52.0 cm)
  • Weight: 49 lbs. (22.23 kg)

 

The Amron International Amcom™ 2810E-ATEX Chamber Communicator is completely self-contained in a thick, premium-grade aluminum enclosure, which prevents gas from getting inside the housing and eliminates the chance of a micro-arc providing an ignition source for flammable gas. Even in the highly unlikely event that gas were to somehow get inside the communicator, the lack of oxygen would trap any gas inside, so there’s no fire or explosion. The communicator is part of a larger explosion-proof system that protects the vessel as a whole.

 

In addition to being explosion-proof, Amron also included some additional design features on the Amcom™ 2810E-ATEX Chamber Communicator. Amron added a special switch that allows the diver to alternate between the inner lock and the outer lock of the chamber. A chamber light on/off switch was installed, allowing the tender to control the power to the light.

The Amron International Amcom™ 2810E-ATEX Chamber Communicator is an explosion-proof, ATEX-rated chamber communicator that can be safely used in a flammable gas environment where there is ignition risk from electrical devices. The 2810E-ATEX provides a means of safe communication with inner and outer locks in a hyperbaric chamber and a method of powering and switching chamber lighting without risk of flammable ignition.

 

The 2810E-ATEX communicator component parts are contained within a thick, premium-grade, IEC Class 1, Zone 2-rated aluminum enclosure that prevents gas from getting into the housing, eliminating the chance of an electrical arc igniting flammable gas. The housing and cable entry glands are sealed, making the enclosure airtight to prevent flammable gas intrusion. The communicator is part of a larger explosion-proof system of ATEX devices intended to protect maritime and industrial vessels operating where flammable gases can accumulate. ATEX devices ensure that electrical equipment, sensors, and enclosures cannot act as ignition sources in these potentially explosive atmospheres.

 

There are 6 operator controls on the front panel of the 2810E-ATEX:

  1. Power On/Off (power for communicator only, not the chamber light)
  2. Light On/Off (controls power to the optional chamber light)
  3. Push-to-Talk (for the operator to speak to chamber occupants)
  4. Lock Selector Switch – Inner, Outer, or Both (selects which lock is monitored)
  5. Lock Volume (controls audio volume for the chamber)
  6. Operator Volume (controls the volume of the operator horn speaker)

 

The communicator works in 2-wire mode only. When the communicator is powered, the horn speaker continuously monitors audio coming from whichever lock is selected on the Chamber Lock Selector switch. The horn speaker functions as both a speaker and microphone. The operator communicates with chamber occupants by speaking into the horn speaker while pressing the push-to-talk button. The operator can speak to the inner lock, outer lock, or both at the same time. The operator can control the volume of the chamber audio and operator audio independently.

 

2810E-ATEX electrical connections are made through a cable pre-installed through a gland at the bottom of the enclosure. There are four functional twisted wire pairs, an earth ground wire, and spare wires in the cable. The four functional twisted pairs are for input power, chamber light power and switching, inner chamber comm box audio, and outer chamber comm box audio. Wires in the cable are pre-labeled for easy identification during installation. The 2810E-ATEX does not have a battery for backup power.

 

Amron offers chamber communications products to use with the 2810E-ATEX inside the chamber:

  • 3115 Chamber Comm Box with Speaker & On/Off Switch
  • 3113 Chamber Comm Box (no push-to-talk switch)
  • 3125 Inner Lock Combo Box with Sound-Powered Phone
  • 3126 Outer Lock Combo Box with Sound-Powered Phone
  • 2460-31R Standard Headset with 4-Pin Audio Connector & Coil Cable (vented)
  • 2401-31R Deluxe Headset with 4-Pin Audio Connector & Straight Cable (vented)
ATTACHMENTS
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone