TESCOM Pressure Reducing Regulator Brass, Inlet 3500 PSIG, Outlet 0-30 PSIG, 1/4 In. NPTF, Cv 0.06, No Gauge Ports, With Panel Mounting
Restrictions / Notifications
- Non-Returnable/Non-Cancelable
This item cannot be canceled or returned once an order has been placed.
Specifications
Teflon® and Vespel® are registered trademarks of E.I du Pont de Nemours and Company. Elgiloy® is a registered trademark of Elgiloy Corp.
CAUTION: This product is cleaned in accordance with the intermediate level of ASTM-G93 and CGA-4.1 (The intermediate level assures removal of visible particles and combustible residues). System designers must verify the compatibility of the materials used in this product before installation and operation. Specification of materials for oxygen service is the user's responsibility. Consult an expert.
NOTICE: This regulator should be serviced on a regular or annual basis under normal usage. For assistance in obtaining the correct soft goods or repair kit SKUs, please contact your Amron representative or email sales@amronintl.com. |
The TESCOM 04 Series is a space-saving and lightweight miniature regulator that offers minimal internal volume and is easy to purge, resulting in less retention.
Applications
- Analyzers
- Lecture bottles
- Sampling systems
Features
- This model has a panel mounting – black knob adjustment.
- No gauge ports.
- Compact size (3 in. / 76 mm high) and constructed with lightweight materials.
- Available in 316 stainless steel, brass, or aluminum body construction.
- Elgiloy® diaphragm provides accurate and stable pressure control.
- Minimal internal volume allows for rapid purging and carryover.
- Corrosion-resistant.
- Various porting configurations are available.
NOTE: When choosing a regulator and control pressure, decaying inlet characteristics must be considered when the supply pressure is expected to change. The decaying inlet characteristic of a pressure-reducing regulator is commonly known as the increase in control pressure due to the decrease in supply pressure. It is important to make sure this effect does not cause the control pressure to exceed the pressure rating of the unit’s outlet or that of the downstream system. For more information on decaying inlet, please refer to the Technical Information section of the product catalog and/or contact TESCOM or AMRON customer support for further assistance.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders