Applications:

  • Commercial Diving / Saturation Diving

Features:

  • Panel Mount SDA CO2 Monitor
  • Color TFT LCD Display
    • Device Identification Label
    • Live Sensor Reading
    • Sensor Type and Display Units
    • System Status Indicator
    • Alarm Direction Indicators
    • Alarm Names
    • Alarm Set-Points
    • Sensor 1 Alarm Values
    • Sensor 2 Alarm Values
  • Adjustment Knob
  • Calibration Adjustment Toggle Switch
  • Alarm Adjustment Toggle Switch
  • Set Button
  • Mute Button

Specifications:

  • SDA Monitor
    • Power Source: External stabilized 12-32V DC supply, (regulation < ±300mV)
    • Operating Current: Average 300mA at 24V DC supply
    • Fuses:
      • Monitor: Internal 2A slow blow micro fuse on monitor PCB:
      • Sensor and data ports: 400mA shutdown protection on +5V DC supply
    • Display Panel:
      • 320 x 240 TFT color graphic display with 10 brightness levels
      • Displays current values of measured parameters using 14 mm high large characters
    • Alarm Indicators: Onscreen visual indication of faults and 2 fully adjustable alarm levels
    • Operator Controls:
      • 2 x momentary action toggle switches for alarm and calibration functions
      • 2 x momentary action push buttons for mute and function selection
      • 1 x rotary encoder for value adjustment and menu navigation
    • Environmental Conditions:
      • Rating: IP22
      • Operating Temperature: 23 to 131° F (-5 to +55° C)
      • Storage Temperature: 14 to 158° F (-10 to +70° C)
      • Operating Pressure: 700 to 1300 mbar absolute
      • Humidity: 0 to 95% RH at 131° F (+55° C) non-condensing
    •  Audio:
      • Speaker: 1W, used for user interface navigation
      • Buzzer: 88dB at 10cm, frequency 2400±400Hz, alarm and fault indication
    • Operational Life: The product is expected to achieve an operational life of at least 10 years with anticipated continuous usage for periods of 30 days in typical applications

MEC CO2 sensor

  • Power Source +5V DC 500mV
  • Operating Current CO2 Sensor: Maximum 390mA at +5V DC supply
  • Detection Mode Infra-red
  • Range and Accuracies 5000ppm CO2: 25ppm CO2, 1% of reading, 2.5ppm CO2 / C 10000ppm (1%) CO2: 50ppm CO2, 1% of reading, 5ppm CO2 / C
  • Response Time T90 in <30seconds
  • Warm Up Time 40 seconds
  • Communication Link RS485 serial data, 9600bps, no parity, 1 stop bit. Distance up to 500m
  • Environmental Conditions Rating: IP22 Operating temperature: -5 to +55°C Storage temperature: -10 to +70°C Operating pressure: 700 to 1300 mbar absolute Humidity: 0 to 95% RH at +55°C non-condensing
  • Dimensions Panel: 2081g Sensor Life 5 years in operation
  • Remote sensor gas flow rate 0.2 to 1.0 liters/minute Maximum sample input pressure 6bara

Optional Accessories:

  • AC-DC +24VDC Panel Mounted Power Supply Unit (PSU)
  • MEC Sensor Only Mounting Plate
  • Combined Mounting Plate (PSU, SDA Output Module and MEC Oxygen Sensor)
  • UK 230VAC Monitor Power Supply - P/N: XK0-662
  • Universal Plug-In Monitor Power Supply - P/N: XK0-667
  • SDA Output Module (Bracket / Panel Mount) - P/N: SDAOMCURRENT
  • SDA Flow Meter Panel (Panel Mount) - P/N: SDAFMPANEL
  • SDA Flow Meter Panel (Rack Mount) - P/N: SDAFMRACK
  • Replacement He (Helium) Sensor - P/N: VQ546MR
  • 5LPM 110L Bottle Regulator - P/N: SA7L705XFLIND
  • Zero Calibration Gas (100% Nitrogen) - P/N: SA7L10308
  • Span Calibration Gas (100% Helium) - P/N: SA7L10501

To read about CO2 EXPOSURE LIMITS IN THE UNITED STATES please click here

Analox SDACBDNXA SDA Monitor and Carbon Dioxide (CO2) Module, Combined Panel, Configured for CO2 0-2% 24VDC

The SDA carbon dioxide monitor provides a full-colour display and can be used alongside a digital sensor like the 5S3 to maintain a comfortable and safe saturation diving chamber.

The SDA carbon dioxide (CO2) monitor provides a full-color display and can be used alongside a digital sensor like the 5S Mk3 to maintain a comfortable and safe saturation diving chamber.

 

The alarm set points and calibration can be achieved using the front panel user interface. The SDA carbon dioxide (CO2) provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs. The SDA carbon dioxide (CO2) monitor interfaces with Analox's state-of-the-art digital 5S Mk3 sensor.

 

The SDA carbon dioxide (CO2) monitor replaces the now obsolete Analox 5001 and is fully retrofittable as a direct replacement.

 

Maintaining a comfortable and safe chamber environment is vital to achieving a successful diving operation. The accuracies supplied by the SDA carbon dioxide monitor are compliant with DNV, IMCA, Lloyds, ABS, and ADCi requirements/guidelines.

 

The SDA carbon dioxide (CO2) monitor is normally located in sat/dive control and can be supplied in rack or panel mount configurations.

 

Its flexibility is what makes it such a good product, as it can suit a wide range of requirements each customer may present. There are a multitude of sensors, alarms and strobes you can attach to one CDU (central display unit). Included in this expansive set up choices are optional add-ons, such as a beacon, a Kiosk set up and a DOM (Data output module).

ATTACHMENTS
file-icon
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!