Not a valid Time
This is a required field.

Kirby Morgan 525-217 Soft Goods Overhaul Kit for Dive Helmet 57

SKU
525-217

Kirby Morgan 525-217 Soft Goods Overhaul Kit for Dive Helmet 57 contains the parts necessary to overhaul the 57 Commercial Diving Helmet.

Restrictions / Notifications

  • Reseller Restriction
    Due to vendor restrictions, this item cannot be sold to a reseller. If you are a reseller, please call us at 760-208-6500 or email sales@amronintl.com for more details.
More Information

Includes

 

PART # DESCRIPTION QTY
205-010 Diaphragm 1
205-015 Inlet Valve Assembly 1
210-050 Adj. Nipple O-Ring 1
510-007 O-Ring 2
510-012 O-Ring 1
510-033 O-Ring 1
510-550 Oral Nasal Valve 1
510-561 Main Exhaust Valve 1
510-776 Exhaust Valve 2
520-023 Bearing Clip 1
520-030 Washer 1
520-031 Washer 1
520-032 Washer 1
520-042 Tie Wrap 4
520-167 Teflon Washer 1
525-019 O-Ring Kit 1
525-032 Whisker Clamp Kit 1
525-330 One-way Valve Kit 1
530-028 Nut 1
540-095 Packing Washer 1
540-531 Lock Clip\, Water-jetted 1

 

 

Kirby Morgan 525-217 Soft Goods Overhaul Kit for Dive Helmet 57 contains the parts necessary to overhaul the 57 Commercial Diving Helmet.

O-rings should be lightly lubricated with food grade silicone Dow Corning 111 or equivalent in accordance with the operations and maintenance manual. Christo-Lube may also be used. At a minimum, all helmet or BandMask o-rings should be replaced at least once a year in accordance with the A2.1 for the helmet or mask being inspected.

During daily and monthly maintenance, disturbed o-rings and valves may be reused providing no damage or deformation is found. O-rings and valves may require replacement more often than yearly if the helmet or mask use is extreme, or if the helmet or mask is used in waters containing oil or chemical contamination. Daily cleaning and inspections as well as performing the monthly inspection A2.2 will identify the need more accurately than simply placing a number of hours between overhaul.

Store spare o-rings, valves and soft goods in a cool, dark, dry place. Avoid prolonged exposure to temperatures above 90 degrees Fahrenheit and/or exposure to ultra violet rays. Do not lubricate exhaust valves. Lubricating valves can cause dirt to stick, allowing leakage.

For detailed directions on installing this kit, please refer to our Attachments tab where there is an instruction pdf available for download.

Please see the Overview tab to see the components of the kit.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone