Not a valid Time
This is a required field.

Hydraulics International Booster Pump - Two Stage - Single Drive - 4,200 psi Max Outlet - 30 psi Min Inlet Pressure

SKU
5G-TS-7/14

Hydraulics International 5G-TS-7/14 Booster Pump is a Two Stage, Single Drive Booster Pump with 4,200 psi Max Outlet Pressure and 30 psi Min Inlet Pressure both based on 95 psi Drive.

Restrictions / Notifications

More Information

Applications

  • Gas Injection: Chemical process, plastic forming.
  • Gas Scavenging: Collecting costly gas in partially used cylinders and transferring it into high-pressure receiver(s) for further use.
  • Pressure testing piping and hardware for leakage, e.g., oil fields, refineries, aircraft, automotive, and instrumentation using gases.
  • Life support gas transfer and charging, e.g., oxygen, helium, breathing air, diving, firefighting/hazmat, aircrew.
  • Compressed natural gas (CNG) boosting for vehicle refueling stations.

 

Features

  • Separation between drive and gas sections uses three dynamic seals with dual vents.
  • Air drive line lubrication is not required.
  • Rugged soft-seat, high-flow check valves in gas section(s).
  • Only hydrocarbon-free stainless steel, bronze, PTFE, and Viton® gas section internal parts are exposed to gas flow.
  • Heat of compression reduced for long seal life because cold exhaust air surrounds gas barrel(s) inside cooling sleeve(s).
  • Standard trim is weatherproof and suitable for offshore service.
  • High pressure capability up to 4,500 psi.
  • Boost directly from unregulated high-pressure gas cylinders or pipelines.
  • Maintain gas purity.
  • One-man portable.
  • No electrical or cooling connections needed.
  • Boost virtually any noncorrosive industrial or laboratory gas.
  • Simple maintenance.
  • Able to mount in any position.
  • Weatherproof and intrinsically safe.

 

Specifications

  • Model Number: 5G-TS-7/14
  • Stages: Two-stage, single drive
  • Approximate Stall Point: (14 x drive air) + (2.00 x gas inlet)
  • Maximum Drive Section Pressure: 150 psi
  • Max Outlet Pressure: 4,200 psi (based on 95 psi drive)
  • Min Inlet Pressure: 30 psi (based on 95 psi drive)
  • Max Safe Pressure Outlet: 4,500 psi
  • Min Safe Pressure Inlet: 2,500 psi
  • Actual Inches Per Cycle: 13.20

 

NOTE: This booster pump is not O₂ cleaned. If the O₂ option is required, please call an Amron representative to assist you further. Domestic U.S.: (877) 462-6700 International: (760) 208-6500.

The Hydraulics International 5G-TS-7/14 Booster Pump is a two-stage, single-drive booster pump with 4,200 psi max outlet pressure and 30 psi minimum inlet pressure, both based on 95 psi drive.

 

An air (or gas) driven gas booster has a continuously reciprocating drive piston section directly connected to one or two gas boosting sections. The drive section includes a four-way air cycling valve and dual air pilot valves to provide the continuous reciprocation. Normally, start/stop control is accomplished by cutting off drive- or pilot air input.

 

The maximum gas section pressures vary by model. The maximum drive section pressure is 150 psi for all models.

 

Most gases used in industry and life support must be clean and dry. Otherwise, the end use is severely compromised. Gases needing purity include argon (Ar), carbon dioxide (CO₂), helium (He), hydrogen (H₂), neon (Ne), nitrogen (N₂), nitrous oxide (N₂O), oxygen (O₂), and breathing air. If gas purity is needed, all devices used to transfer gas or increase gas pressure must be completely dry and free of any lubricants. Hydraulics International, Inc.’s (HII’s) air-driven gas boosters satisfy this requirement. No hydrocarbon lubrication is needed in the gas sections because the high-pressure pistons slide on inert PTFE dynamic seals. And because gas barrel temperature is controlled with the cold drive air exhaust, long seal life is ensured.

 

Most mechanically driven gas compressors can only handle 5,000 to 6,000 psi requirements. Mechanically driven units that can handle over 6,000 psi are rare and costly. If gas purity is required, most of these higher psi units need high-pressure and high-maintenance purifiers installed to compensate for hydrocarbon carryover created by oil-lubricated pistons. Air-driven gas boosters do not suffer from these shortcomings and are therefore better suited for higher psi applications. HII’s standard air-driven models are hydrocarbon-free and available in 50- to 25,000 psi capacities.

 

A mechanical compressor cannot inhale common industrial gas cylinder pressure. The inlet pressure must be reduced, usually close to 0 psi. This is a costly waste of energy. Air-driven gas boosters have no such limitation, greatly enhancing the efficiency and simplicity of high-pressure gas applications where the gas source is typically supplied from portable DOT cylinders.

 

NOTE: This booster pump is not O₂ cleaned. If the O₂ option is required, please call an Amron representative to assist you further. Domestic U.S.: (877) 462-6700. International: (760) 208-6500.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone