Draeger Detector Tube Carbon Dioxide
Only %1 left
SKU
DETECTORTUBECARBONDIOXIDE
As low as
$105.93
These gas detection tubes allow for the measuring carbon dioxide.
Features:
- For use in occupational health & safety settings.
Specifications:
- Item 6728521:
- Only use for decompressed compressed air.
- A conclusion regarding the CO2 content in the entire pressure system is not possible.
- Quantity: 10 tubes per box
Important Note: These tubes are only to be used with Dräger Test Kits.
| Item |
Carbon Dioxide Dräger Tube |
Applications | Measurement Range | Maximum Operating Temperature | Minimum Operating Temperature | Sampling Time | Color Change |
| 6728521 | 100/a-P |
|
100 to 3,000 ppm | 77 °F | 59 °F | 5 minutes | White to Violet |
| 8101811 | 100/a |
|
100 to 3,000 ppm | 77 °F | 59 °F | 4 minutes | White to Pale Violet/Blue Violet |
| CH20301 | 5%/a |
|
5 to 60% vol | 104 °F | 32 °F | 2 minutes | White to Violet |
| CH23501 | 0.1%/a |
|
0.5 to 6% vol/0.1 to 1.2% vol | 86 °F | 32 °F |
30 seconds/ 2.5 minutes |
White to Violet |
| CH25101 | 1%/a |
|
1 to 20% vol | 104 °F | 32 °F | 30 seconds | White to Violet |
| CH31401 | 0.5%/a |
|
0.5 to 10% vol | 104 °F | 32 °F | 30 seconds | White to Violet |
Restrictions / Notifications
- CA PROP65
Warning: Cancer and Reproductive Harm www.p65warnings.ca.gov - MSDS
Safety Data Sheet available online or by request.
These gas detection tubes allow for the measuring carbon dioxide.
Features:
- For use in occupational health & safety settings.
Specifications:
- Item 6728521:
- Only use for decompressed compressed air.
- A conclusion regarding the CO2 content in the entire pressure system is not possible.
- Quantity: 10 tubes per box
Important Note: These tubes are only to be used with Dräger Test Kits.
| Item |
Carbon Dioxide Dräger Tube |
Applications | Measurement Range | Maximum Operating Temperature | Minimum Operating Temperature | Sampling Time | Color Change |
| 6728521 | 100/a-P |
|
100 to 3,000 ppm | 77 °F | 59 °F | 5 minutes | White to Violet |
| 8101811 | 100/a |
|
100 to 3,000 ppm | 77 °F | 59 °F | 4 minutes | White to Pale Violet/Blue Violet |
| CH20301 | 5%/a |
|
5 to 60% vol | 104 °F | 32 °F | 2 minutes | White to Violet |
| CH23501 | 0.1%/a |
|
0.5 to 6% vol/0.1 to 1.2% vol | 86 °F | 32 °F |
30 seconds/ 2.5 minutes |
White to Violet |
| CH25101 | 1%/a |
|
1 to 20% vol | 104 °F | 32 °F | 30 seconds | White to Violet |
| CH31401 | 0.5%/a |
|
0.5 to 10% vol | 104 °F | 32 °F | 30 seconds | White to Violet |
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone