Not a valid Time
This is a required field.

Nuvair Carbon Dioxide (CO2) Sensor Replacement for Pro Carbon Dioxide (CO2) Analyzers

SKU
NUV-9616-SEN
$1,369.00
Eligible for Free Shipping Over $125
CO2 SENSOR ONLY; 2000 PPM

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
  • CA PROP65
    Warning: Cancer and Reproductive Harm www.p65warnings.ca.gov
  • MSDS
    Safety Data Sheet available online or by request.
More Information

Features:

  • Replacement carbon dioxide (CO2) sensor for the following Nuvair Pro CO2 analyzers:
    • 9616
    • 9617

    Specifications:

    • Flow Rate: 0.6-1 L/min
    • Resolution: 50 ppm resolution from 0 to 1000 ppm, then 100 ppm up to full scale.
    • Repeatability: ± 2% of full scale @ 68°F (20°C) ambient.
    • Linearity: At ambient temperature and pressure: ± 2% FSD or ± 10% of the reading, whichever is greater.
    • Sensor Type: NDIR (Non-dispersive infrared)
    • Expected Sensor Life: 5-10 years based on analyzer handling and use.
    • Replacement Procedure: Sensor can be replaced by the user.
    • Range: 0-2,000 ppm
    • Operating & Storage Temperature: -4° to +122°F (-20° to +50°C)
    • Operating Humidity: 0 to 95% rh, non-condensing
    • Weight: 0.2 oz. (6 g)

    * All specifications are at ambient/sea level, 77°F (25°C) and are subject to change without notice. Calibration must be confirmed with a calibration CO2 test gas.

    *WARNING: Never expose gas sensors to pressure or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required. A faulty Flow Restrictor can lead to a false analyzer reading. Flow Restrictors should be regularly tested with a Flow Meter. Inaccurate gas analysis can lead to serious personal injury or death..

Nuvair's Carbon Dioxide (CO2) Sensor Replacement for Pro Carbon Dioxide (CO2) Analyzers NUV-9616-SEN is a replacement for the following Nuvair Pro CO2 analyzers: 9603, 9604-LB 9615-LB, 9615.5-LB, 9616, 9617, 9635, and 9641-NV.
ATTACHMENTS
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone