Analox Sub MkIIIF w/REM1-REM2 (0-3000 mBar pO2 / 0-20 mBar pCO2)
Analox ASF3AEDACYY Sub MKIIIF with REM1-REM2; 0-3000 mBar pO2; 0.00-20.00mBar pCO2 0.50-10.00 BarA; 0.0-50 Degrees Celcius; 0-100% RH includes 24VDC Power Adapter; Data Logging and Relay/Outputs as Standard. The Analox Sub Mk IIIF is a hyperbaric atmosphere monitoring system capable of measuring oxygen (O2), carbon dioxide (CO2), pressure (depth) temperature and relative humidity.
Restrictions / Notifications
- Non-Returnable/Non-Cancelable
This item cannot be canceled or returned once an order has been placed.
The P/N: ASF3AEDACYY are for a Sub Mk IIIF system designed to work up to 3BarA. The O2 sensor range is ideal for medical chamber use where the CO2 range is to ensure the CO2 levels remain below safe levels within a decompression chamber. Basic installation might consist of an operator console with a REM1 and an optional REM2. Power is 24V as standard with external power supply provided as an optional extra. Features:
Specifications:
Sensor Measurment Techniques:
To read about CO2 EXPOSURE LIMITS IN THE UNITED STATES please click here Features
Specifications
Sensor Measurement Techniques
|
The Analox Sub MkIIIF with REM1-REM2 includes 24VDC Power Adapter, Data Logging, and Relay/Outputs as Standard. The Analox Sub Mk IIIF is a hyperbaric atmosphere monitoring system capable of measuring oxygen (O2), carbon dioxide (CO2), pressure (depth), temperature, and relative humidity. It is ideal for use in hyperbaric chambers for HBOT or diving and for monitoring the atmosphere in Submarine Rescue Vehicles (SRV’s).
The Sub MkIIIF can also be configured as an O2 controller to automatically maintain oxygen concentrations to a preset level. The O2 controller would typically be used to maintain the chamber oxygen concentration or the oxygen concentration delivered from a bibs system on an SRV.
The Sub MkIIIF consists of a main control panel (operator console) and a number of remote sensor modules (REM’s). A large graphic display on the operator console shows the value of each measured parameter, units of measurement, and alarm set points. Two audio/visual alarm channels are available for each measured parameter. The REM’s provide local in chamber displays of the monitored parameters and repeat the audiovisual alarm status.
The O2 sensor range is ideal for medical chamber use, where the CO2 range is to ensure the CO2 levels remain below safe levels within a decompression chamber. Basic installation might consist of an operator console with a REM1 and an optional REM2. Power is 24V as standard with external power supply provided as an optional extra.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
-
Analox Replacement Sensor Carbon Dioxide (CO2) 0-20 MBAR MIR Sensor in N2 for Sub MkIIIFSKU: MIRAGNX4S$3,445.20