Analox Sub MkIIIF w/REM1-REM2 (0-3000 mBar pO2 / 0-20 mBar pCO2)

SKU
ASF3AEDACYY
$35,663.04
Eligible for Free Shipping Over $125

Analox ASF3AEDACYY Sub MKIIIF with REM1-REM2; 0-3000 mBar pO2; 0.00-20.00mBar pCO2 0.50-10.00 BarA; 0.0-50 Degrees Celcius; 0-100% RH includes 24VDC Power Adapter; Data Logging and Relay/Outputs as Standard. The Analox Sub Mk IIIF is a hyperbaric atmosphere monitoring system capable of measuring oxygen (O2), carbon dioxide (CO2), pressure (depth) temperature and relative humidity.

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
More Information

The P/N: ASF3AEDACYY are for a Sub Mk IIIF system designed to work up to 3BarA. The O2 sensor range is ideal for medical chamber use where the CO2 range is to ensure the CO2 levels remain below safe levels within a decompression chamber. Basic installation might consist of an operator console with a REM1 and an optional REM2. Power is 24V as standard with external power supply provided as an optional extra.

Features: 

  • Real time in chamber information: In chamber and out of chamber readouts of the monitored parameters
  • Infrastructure associated with external analysers: All sample lines required
  • Minimises downtime:
    • Oxygen and carbon dioixde sensors are field replaceable
    • Temperature and humidity module changed at service intervals
  • Data outputs as standard: Offering real time data on a serial port for logging or displaying on an external system

Specifications:

  • 0 to 3000mBar ppO2
  • 0.00 20.00mBar ppCO2
  • 0.80 to 10.00 BarA
  • 0 to 50oC
  • 0 to 100% RH
  • Range CO2: 0 to 20.00 mBar, 0 to 100.0 mBar
  • Range O2: 0 to 1500 mBar pO2, 0 to 3000 mBar pO2
  • Range Depth: 0.50 to 10.00 BarA, 0.50 to 60.00 BarA
  • Range Temperature: 0 to +50oC
  • Range Humidity: 0 to 100% RH
  • Operating Temp: 0 to +50oC
  • Power Options: 12 to 30 VDC
  • Outputs: 8 x 4 to 20mA channels
  • Alarms:
    • 1 alarm indicator for gas/environment alarms
    • 1 fault indicator for communications, calibration and general system faults
  • Dimensions mm:
    • Operator Console 260x160x90
    • Sensor Modules 90x140x55
  • Data output:
    • Real time data output on serial port for logging or display on external system

Sensor Measurment Techniques:

Parameter Technology Location
Oxygen Electrochemical REM 1
Carbon dioxide Infra-red absorption REM 1
Pressure Strain gauge REM 1
Temperature Platinum resistor REM 2
Humidity Capacitive REM 2

To read about CO2 EXPOSURE LIMITS IN THE UNITED STATES please click here

Features
  • Real time in chamber information, providing in chamber and out of chamber readouts of the monitored parameters.
  • Infrastructure associated with external analyzers; all sample lines required.
  • Oxygen and carbon dioxide sensors are field replaceable.
  • Temperature and humidity module changed at service intervals.
  • Data outputs as standard, offering real time data on a serial port for logging or displaying on an external system.

 

Specifications
  • Pressure Range:
    • O2: 0 to 3000 mBar
    • CO2: 0 to 20 mBar
    • 0.80 to 10.00 BarA
  • Temperature Range: 32 to 122°F/0 to 50°C
  • Relative Humidity: 0 to 100%
  • Power Options: 12 to 30 VDC
  • Outputs: 8 x 4 to 20mA channels
  •  Alarms:
    • 1 alarm indicator for gas/environment alarms
    • 1 fault indicator for communications, calibration, and general system faults
  • Dimensions:
    • Operator Console: 260 mm x 160 mm x 90 mm
    • Sensor Modules: 90 mm x 140 mm x 55 mm
 
Sensor Measurement Techniques
Parameter Technology Location
Oxygen Electrochemical REM 1
Carbon dioxide Infra-red absorption REM 1
Pressure Strain gauge REM 1
Temperature Platinum resistor REM 2
Humidity Capacitive REM 2

The Analox Sub MkIIIF with REM1-REM2 includes 24VDC Power Adapter, Data Logging, and Relay/Outputs as Standard. The Analox Sub Mk IIIF is a hyperbaric atmosphere monitoring system capable of measuring oxygen (O2), carbon dioxide (CO2), pressure (depth), temperature, and relative humidity. It is ideal for use in hyperbaric chambers for HBOT or diving and for monitoring the atmosphere in Submarine Rescue Vehicles (SRV’s).

 

The Sub MkIIIF can also be configured as an O2 controller to automatically maintain oxygen concentrations to a preset level. The O2 controller would typically be used to maintain the chamber oxygen concentration or the oxygen concentration delivered from a bibs system on an SRV.

 

The Sub MkIIIF consists of a main control panel (operator console) and a number of remote sensor modules (REM’s). A large graphic display on the operator console shows the value of each measured parameter, units of measurement, and alarm set points. Two audio/visual alarm channels are available for each measured parameter. The REM’s provide local in chamber displays of the monitored parameters and repeat the audiovisual alarm status.


The O2 sensor range is ideal for medical chamber use, where the CO2 range is to ensure the CO2 levels remain below safe levels within a decompression chamber. Basic installation might consist of an operator console with a REM1 and an optional REM2. Power is 24V as standard with external power supply provided as an optional extra.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!