Analox SDARBBNXA SDA Carbon Dioxide (CO2) Monitor - Rack Mount - 0 to 5000 ppm in N2
The Analox SDA CO2 offers users the latest digital technology in commercial diving gas detection.
The Analox SDA series is a range of fixed external chamber analyzers used to control levels of gases such as oxygen and carbon dioxide. The new products are designed to be more easily configured to meet the users’ needs, with interchangeable sensors and software.
Restrictions / Notifications
- Non-Returnable/Non-Cancelable
This item cannot be canceled or returned once an order has been placed.
Features:
Specifications:
To read about CO2 EXPOSURE LIMITS IN THE UNITED STATES please click here |
The Analox SDA CO2 offers users the latest digital technology in commercial diving gas detection.
The Analox SDA series is a range of fixed external chamber analyzers used to control levels of gases such as oxygen and carbon dioxide. The new products are designed to be more easily configured to meet the users’ needs, with interchangeable sensors and software.
The SDA carbon dioxide (CO2) monitor provides a full-color display and can be used alongside a digital sensor like the 5S Mk3 to maintain a comfortable and safe saturation diving chamber.
The alarm set points and calibration can be achieved using the front panel user interface. The SDA carbon dioxide (CO2) provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs. The SDA carbon dioxide (CO2) monitor interfaces with Analox's state-of-the-art digital 5S Mk3 sensor.
The SDA carbon dioxide (CO2) monitor replaces the now obsolete Analox 5001 and is fully retrofittable as a direct replacement.
Maintaining a comfortable and safe chamber environment is vital to achieving a successful diving operation. The accuracies supplied by the SDA carbon dioxide monitor are compliant with DNV, IMCA, Lloyds, ABS, and ADCi requirements/guidelines.
The SDA carbon dioxide (CO2) monitor is normally located in sat/dive control and can be supplied in rack or panel mount configurations.
Its flexibility is what makes it such a good product, as it can suit a wide range of requirements each customer may present. There are a multitude of sensors, alarms and strobes you can attach to one CDU (central display unit). Included in this expansive set up choices are optional add-ons, such as a beacon, a Kiosk set up and a DOM (Data output module).
FAQ's
The SDA has a very intuitive rotary encoder dial, this coupled with the familiar retro toggle switches and appropriate zero and span gases will mean that these analyzers are easier to calibrate than others you may have used.
The SDA does not offer a battery back up option as the vast majority of diving systems now have un-interrupted power supply.
Not at all – each SDA is configured for 24VDC power as standard but you can purchase an Analox 24VDC mains power supply which is capable of powering 2 SDA modules and their accessories.
Yes, the SDA comply with DNVs offshore standard E402 and IMCA guidelines in that they comply with the accuracy and feature requirements.
No, the O2 sensors used with the SDA are new and intelligent sensors which will signal when they need calibrating and changing. They also have the added benefit of having the ability to be positioned as far away from the monitor as you wish; unlike current analogue systems.
Yes. The SDA O2 will fit directly into the existing panel space.
If your current 5001 CO2 unit is a combined panel mount you will also need the “5001 Compatibility Plate” to mount the SDA rack monitor and CO2 module. If your current 5001 CO2 unit is a combined rack mount, the SDA will fit direct.
The SDA CO2 uses the new Analox 5S3 transducer. This twin beam, highly precise infra-red sensor will offer un-rivaled stability and reliability, requiring minimal adjustments during regular saturation diving operations.
Yes, please contact us to discuss the special version of the compatibility plate you will require along with the range of the unit. Please note that the SDA is not USN codified.
No.
You are able to buy an SDA monitor configured for O2 without the sensor. If you then purchase the configuration software you can then configure the unit to be used as a CO2 unit. This is designed to offer users more flexibility when managing spares.
You can also access other features on this CD such as training videos and other features such as the on screen naming of your monitor to correspond with a particular chamber or lock.
90 days of continual logging. The oldest data is then over-written.
No, unfortunately the datalogging feature can only be added at the factory.
Yes – this option is on the basic on screen menu accessed with the buttons on the monitor itself.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone