Analox SDA Temperature & Humidity Combined Monitor (Chamber Version)

SKU
SDARDGXXA
$3,684.45
Eligible for Free Shipping Over $125
SDA MONITOR TH PROBE CHAMBER VERSION RACKMOUNT

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
More Information
Features
  • The SDA Temperature & Humidity is available in 2 formats, both using the same user-friendly monitor which displays both temperature (in °C or  °F) and humidity levels on a large full color screen where alarm set points can be easily adjusted at the monitor.
  • These units replace the now obsolete Analox 4000 & 7000 monitors.

  • The standard (chamber) version, where the sensor is simply mounted inside the chamber, is ideal for monitoring levels in a hyperbaric chamber, lifeboat or diving bell to help ensure a comfortable and safe living and working environment is maintained in line with industry guidelines.

  • Available in either rack or panel mount versions and with the option of adding data-logging at the time of purchase.

  • Compatible with the SDA Output Module so if relays or a 4-20mA output is required then this can be simply added when required.

 

Specifications
  • SDA Monitor & Temperature and Humidity probe.
  • Chamber version.
  • Includes rack mount.
  • Temperature Range: 32-212°F / 0-100°C
  • Relative Humidity: 0-100% RH
  • 24V DC

The SDA Temperature & Humidity is available in 2 formats, both using the same user-friendly monitor which displays both temperature (in °C or  °F) and humidity levels on a large full color screen where alarm set points can be easily adjusted at the monitor. These units replace the now obsolete Analox 4000 & 7000 monitors.

 

The standard (chamber) version, where the sensor is simply mounted inside the chamber, is ideal for monitoring levels in a hyperbaric chamber, lifeboat or diving bell to help ensure a comfortable and safe living and working environment is maintained in line with industry guidelines.

 

The inline version, where the sensor is mounted inside the gas pipework, is ideal for monitoring the breathing gas supply temperature and humidity in line with classification requirements such as the ABS rules for building and classing underwater vehicles, systems and hyperbaric facilities (Gas Reclaim Systems section).

 

Both versions are available in either rack or panel mount versions and with the option of adding data-logging at the time of purchase. They are also compatible with the SDA Output Module so if relays or a 4-20mA output is required then this can be simply added when required.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone