Analox Portable Oxygen (O2) Monitor

SKU
MO2BGYY01
$658.30
Eligible for Free Shipping Over $125

The O2 Portable Oxygen Analyser is designed to measure oxygen levels in the range 0.1 100% O2. The analyser should be used for cylinder oxygen level verification or for monitoring a gas mixing panel but should not be used for both. If the analyser is used for measuring the oxygen level in the output from a mixing panel, another O2 Portable should be used for cylinder verification purposes.

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
More Information

Features:

  • US Navy approved
  • Water and drop resistant
  • Portable, fast and accurate
  • Large digital display with low battery warning symbol
  • Internal O2 sensor for protection and to minimize the effects of temperature
  • 9V alkaline battery gives long life up to 3 years of intermittent operation before replacement
  • Designed specifically for the Diving Industry, Sport (NITROX),Commercial and Military - where hostile environmental conditions are the norm not the exception

Specifications:

  • Range: 0.1-100% Oxygen
  • Accuracy: 1% of 0-50% calibrated on air, 2% of reading over range 0-100% calibrated Oxygen
  • Resolution: ± 0.1 % Oxygen
  • Display: 3-1/2 in. Digital LCD
  • Operating Temp: 23° to 122° F (-5° to 50° C)
  • Sensor Life: 2 year limited warranty in air at Normal Temperature and Pressure
  • Sensor Response: Less than 15 seconds to 90% of final reading
  • Flow Rate: 0.5 to 2.5 liters/min. using flow adapter (1 LPM recommended)
  • Dimensions: 3.86 in. H x 2.5 in. W(64 mm) x 1.5 in. D (98 mm x 64 mm x 36 mm)
  • Weight: 7.0 oz. (200 g)

Analox Portable Oxygen Monitor: Part Number MO2BGYY01 Includes:

  • (1) Internal O2 Sensor - P/N: 9100-9212-5AD
  • (1) Standard Flow Adaptor (one spigot) - P/N: MIO2FA
  • (1) DII Flow Adaptor (one spigot) - P/N: 8000-0002A
  • (1) One Meter Black Rubber Tubing - P/N: MIO2HO
  • (1) 9V Alkaline Battery

Pairs with the following items:

  • Replacement Oxygen (O2) Sensor for the Portable Oxygen (O2) Monitor P/N: 9100-9212-5AD
  • Flow Adapter for the Portable Oxygen (O2) Monitor and the HYP Hyperbaric Portable Oxygen (O2) Partial Pressure Analyzer P/N: 8000-0011GA
Features
  • US Navy approved.
  • Water and drop resistant.
  • Portable, fast, and accurate.
  • Large digital display with low battery warning symbol.
  • Internal O2 sensor for protection and to minimize the effects of temperature.
  • 9V alkaline battery gives long life, up to 3 years of intermittent operation before replacement.
  • Designed specifically for the diving, sport (nitrox), commercial, and military industries.
  • Includes:
    • (1) Internal O2 Sensor (P/N: 9100-9212-5AD)
    • (1) Standard Flow Adaptor (one spigot) (P/N: MIO2FA)
    • (1) DII Flow Adaptor (one spigot) (P/N: 8000-0002A)
    • (1) One Meter Black Rubber Tubing (P/N: MIO2HO)
    • (1) 9V Alkaline Battery
Specifications
  • Range: Oxygen (O2) 0.1-100%
  • Accuracy:
    • Air: 1% of 0-50% calibrated on air
    • Oxygen: 2% of reading over range 0-100% calibrated oxygen
  • Resolution: ± 0.1 % Oxygen
  • Display: 3-1/2 in. Digital LCD
  • Temperature Range: 23° to 122° F (-5° to 50° C)
  • Sensor Life: 2-year limited warranty in air at normal temperature and pressure
  • Sensor Response: Less than 15 seconds to 90% of final reading
  • Flow Rate: 0.5 to 2.5 liters/minute using flow adapter (1 LPM recommended)
  • Dimensions: 3.86 in. H x 2.5 in. W x 1.5 in. D (98 mm H x 64 mm W x 36 mm D)
  • Weight: 7.0 oz. (200 g)
  • Compatible with the following items:
    • Replacement Oxygen (O2) Sensor for Portable Oxygen (O2) Monitor (P/N: 9100-9212-5AD)

    • Flow Adapter for Portable Oxygen (O2) Monitor and HYP Hyperbaric Portable Oxygen (O2) Partial Pressure Analyzer (P/N: 8000-0011GA)

The O2 Portable Oxygen Analyzer is designed to measure oxygen levels in the oxygen range 0.1 to 100%. The analyzer should be used for cylinder oxygen level verification or for monitoring a gas mixing panel but should not be used for both. If the analyzer is used for measuring the oxygen level in the output from a mixing panel, another O2 Portable should be used for cylinder verification purposes.


The O2 Portable has a large digital display and operates from an internal temperature compensated 3 year life (expected) electrochemical oxygen sensor. Power is provided by a 9V, 4000-hour life battery giving up to 3 year operation before replacement is necessary. The O2 Portable is a water-resistant drop resistant completely self-contained unit designed specifically for diving, sport (nitrox), commercial and military industries.

FAQ's
Can I replace the sensor myself?

Yes, but you should follow the procedure listed below or in section 7 of the user manual.

Sensor replacement procedures.

a) Replacement sensor part number: 9100-9212-5AD
b) Remove the 4 screws located at each corner of the unit and carefully lift the lid.
c) Remove the flow adapter if fitted and slide the sensor out of the lid.
d) Disconnect the inline sensor connector.
e) Dispose of the old sensor according to local regulations for Lead and Potassium Hydroxide solution.
f) Remove the new sensor from its bag and check it for leaks, connect to the inline connector and slide through the lid.
g) Replace the lid carefully and screw down taking care that the sensor locates properly. Ensure that you do not trap any wires.

Can I replace the battery myself once it has expired in the Portable Oxygen Monitor?

Yes, this is simple but we recommend that you follow the procedure in the user manual.

My reading doesn’t change when I turn the calibration knob – what should I do?

It is most likely that you need to purchase a replacement sensor although it is worth checking the connections first.

How often should I calibrate my O2 Portable?

It is recommended to calibrate your unit before every use.

How do I calibrate the unit?

Please refer to the user manual.

I have a zero reading – what should I do?

Check the sensor connection. If this is fine then it is likely that you need a replacement sensor.

I have a “9100-9212-5A” cell in my unit. Is the “9100-9212-5AD” compatible?

The “9100-9212-5AD” cell has replaced the “9100-9212-5A” and the “9100-9212-5D” cells and is 100% compatible.

What is the difference between the Analox O2DII and the Analox O2 Portable?

There is no difference. The name was changed in 2008.

Is the O2 Portable water resistant?

Although designed to be water resistant the O2 Portable should not be intentionally immersed in liquid.

How long does the battery last?

Approx 4000 hours (Over 166 days!).

My reading doesn’t change to the desired reading when I turn the calibration pot – what should I do?

It is likely that your sensor needs replacing, please contact your Amron Sales Representative to purchase a new sensor.

Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
We found other products you might like!
  1. Analox Certificate of Conformance for Analox Analyzers with Traceable Serial Number - ANALOX-CERTCONFORM
    Analox Certificate of Conformance for Analox Analyzers w/Traceable Serial Number
    SKU: ANALOX-COC-SN