Analox Portable Oxygen (O2) Monitor
The O2 Portable Oxygen Analyser is designed to measure oxygen levels in the range 0.1 100% O2. The analyser should be used for cylinder oxygen level verification or for monitoring a gas mixing panel but should not be used for both. If the analyser is used for measuring the oxygen level in the output from a mixing panel, another O2 Portable should be used for cylinder verification purposes.
Restrictions / Notifications
- Non-Returnable/Non-Cancelable
This item cannot be canceled or returned once an order has been placed.
Features:
Specifications:
Analox Portable Oxygen Monitor: Part Number MO2BGYY01 Includes:
Pairs with the following items:
Features
Specifications
|
The O2 Portable Oxygen Analyzer is designed to measure oxygen levels in the oxygen range 0.1 to 100%. The analyzer should be used for cylinder oxygen level verification or for monitoring a gas mixing panel but should not be used for both. If the analyzer is used for measuring the oxygen level in the output from a mixing panel, another O2 Portable should be used for cylinder verification purposes.
The O2 Portable has a large digital display and operates from an internal temperature compensated 3 year life (expected) electrochemical oxygen sensor. Power is provided by a 9V, 4000-hour life battery giving up to 3 year operation before replacement is necessary. The O2 Portable is a water-resistant drop resistant completely self-contained unit designed specifically for diving, sport (nitrox), commercial and military industries.
FAQ's
Yes, but you should follow the procedure listed below or in section 7 of the user manual.
Sensor replacement procedures.
a) Replacement sensor part number: 9100-9212-5AD
b) Remove the 4 screws located at each corner of the unit and carefully lift the lid.
c) Remove the flow adapter if fitted and slide the sensor out of the lid.
d) Disconnect the inline sensor connector.
e) Dispose of the old sensor according to local regulations for Lead and Potassium Hydroxide solution.
f) Remove the new sensor from its bag and check it for leaks, connect to the inline connector and slide through the lid.
g) Replace the lid carefully and screw down taking care that the sensor locates properly. Ensure that you do not trap any wires.
Yes, this is simple but we recommend that you follow the procedure in the user manual.
It is most likely that you need to purchase a replacement sensor although it is worth checking the connections first.
It is recommended to calibrate your unit before every use.
Please refer to the user manual.
Check the sensor connection. If this is fine then it is likely that you need a replacement sensor.
The “9100-9212-5AD” cell has replaced the “9100-9212-5A” and the “9100-9212-5D” cells and is 100% compatible.
There is no difference. The name was changed in 2008.
Although designed to be water resistant the O2 Portable should not be intentionally immersed in liquid.
Approx 4000 hours (Over 166 days!).
It is likely that your sensor needs replacing, please contact your Amron Sales Representative to purchase a new sensor.
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.Phone
Toll-Free: (877) 462-6700Local & International: (760) 208-6500
Fax: (760) 599-3857
Hours of Operation
Customer ServiceMonday - Friday, 8am – 5pm Pacific Time Zone
Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone
-
Analox Replacement Oxygen (O2) Sensor for Portable Oxygen (O2) MonitorSKU: 9100-9212-5ADSHIP NOW$257.95List Price: $285.65