Analox O2NE+ Oxygen (O2) Depletion Wall Mounted Analyzer w/Quick Connect Repeater

Only %1 left
SKU
AX1BK10XXXQXY01

Restrictions / Notifications

  • Non-Returnable/Non-Cancelable
    This item cannot be canceled or returned once an order has been placed.
More Information
Features
  • Simple to use, long life, wall mounted monitor for oxygen deficiency, provided with factory set audiovisual alarms at 19.5% and 18% O2, making it ideal for monitoring oxygen levels where inert gases such as N2, Ar or He pose a risk of depleting O2 levels. 
  • Easy calibration using certified air is only required every 12 months, reducing ongoing maintenance requirements.
  • Long life sensor is designed to last 7 years and can then be easily changed out.
  • These units consist of a main sensor unit, to be located in the area where a gas leak poses a risk, and a remote repeater unit, which is to be located outside the main entry door to the risk area.
  • The remote repeater mimics the information from the sensor unit, so you can ensure it is safe before you enter.

 

Specifications
  • Base Unit: Analox AX1
  • Sensor Range: 0-25%
  • Alarms: 18/19.5 - O2NE+ unlatched
  • Display: Fitted
  • Power Supply Options:
    • 230V AC EU
    • 230V AC UK
    • 110V AC US
  • Repeater Options:
    • Quick Connect (No Strobe)
    • Quick Connect w/High Intensity Strobe
  • Output Options:
    • No Output
    • 0-1v
    • 2 Relays (one per alarm)
  • OEM/Language Options:
    • English O2NE+
    • CSA English O2NE+

The O2NE+ is a cost-effective, simple to use, long life, wall mounted monitor for oxygen deficiency, provided with factory set audiovisual alarms at 19.5% and 18% O2, making it ideal for monitoring oxygen levels where inert gases such as N2, Ar or He pose a risk of depleting O2 levels.

 

Easy calibration using certified air is only required every 12 months, reducing ongoing maintenance requirements (standard oxygen monitors require 6 monthly calibration and sensor swap out approx. every 2 years). The long life sensor is designed to last 7 years and can then be easily changed out. These units consist of a main sensor unit, to be located in the area where a gas leak poses a risk, and a remote repeater unit, which is to be located outside the main entry door to the risk area. The remote repeater mimics the information from the sensor unit, so you can ensure it is safe before you enter.

 

If you are only using CO2, it is most likely that you require a CO2 monitor (such as our Ax60) and NOT an O2 monitor.

ATTACHMENTS
Amron International Customer Service
We respond to most inquiries within 24 hours, Monday – Friday, excluding holidays.
Phone
Toll-Free: (877) 462-6700
Local & International: (760) 208-6500
Fax: (760) 599-3857
Email
sales@amronintl.com
Hours of Operation
Customer Service
Monday - Friday, 8am – 5pm Pacific Time Zone

Warehouse/Will Call Orders
Monday – Friday, 9am – 3:30pm Pacific Time Zone