Request a Quote

Please fill out the following form below.

PECI Tactical Flotation Support System 5326 - MOLLE Pouch

Be the first to review this product

SKU: TFSS-5326-O-BL-M-CO2

$490.00

Availability: Contact us for availability

Restrictions / Notifications

  • This item contains hazardous materials and does not qualify for any free shipping promotions.
  • PECI Flotation Tactical Flotation Support System 5326 - MOLLE Pouch

PECI Flotation Tactical Flotation Support System 5326 - MOLLE Pouch

Double click on above image to view full picture

Zoom Out
Zoom In
Overview

Features

  • Minimum Buoyancy per Unit: 40 lbs. lift in seawater, at the surface, with air and water temperature of 70° F (approximately 22 lbs. lift at 33 ft. sea water)
  • Minimum Buoyancy per System: 80 lbs. lift in seawater, at the surface,with air and water temperature of 70° F (approximately  45 lbs.  lift  at  33 ft. sea water)
  • Manual Inflation: Left and right manually operated CO2 systems
  • Oral Inflation: Left and right oral inflation tubes
  • CO2 Cylinders: Left and right CO2 gas cylinders (purchased separately)
  • Corrosion Resistance: All parts are corrosion resistant in fresh and salt water
  • Rot Resistance: All fabric, webbing, and binding are rot resistant
  • System Identification: Each pair is identified by the manufacture date and a space is provided for an organization's unique serial number. Left side unit identified with the suffix "L"; right side unit identified with the suffix "R". Each unit is marked individually.
  • Unique Grommet, Loop, and Pin (GLP) Closure System
Descriptions

The PECI Tactical Flotation Support System 5326 is an inflatable aid to flotation devices specifically designed for covert war fighters, combat swimmers, and/or maritime airborne operations personnel. It can also be used with the Helicopter Aircrew Breathing Device (HABD) during egress from a submerged vessel of any type. The PECI Tactical Flotation Support System 5326 was designed to provide 45 lbs. positive buoyancy in seawater at a depth of 33 ft., 57 lbs. of positive flotation at a depth of 15 ft., and 80 lbs. of flotation on the surface, allowing today's war fighter a maximum load-out of equipment.

Each PECI Tactical Flotation Support System 5326 system consists of one each independent left and right hand units, which can be mounted on a belt. Each unit includes a welded flotation bladder, an inflation system, a pouch closure system, a pouch, and a firing handle. The bladder is a reusable welded fabric enclosure that deploys under the arm and is readily collapsed and stowed for future use. The inflation system utilizes a manually actuated CO2 cartridge for primary inflation and an oral inflation tube for secondary inflation.

The pouch of the PECI Tactical Flotation Support System 5326 uses a unique Grommet, Loop, and Pin (GLP) closure system design that combines positive closure of the pouch with space efficient packing. This method prevents accidental pouch opening and allows for the smallest unit size when fully packed (approx 6.5 in. x 2.75 in. x 2.25 in). A durable Cordura flap to further protect against damage and inadvertent actuation covers the entire closure mechanism.

The PECI Tactical Flotation Support System 5326's pouch contains and protects the bladder, inflation system, and closure system. It includes a waist belt loop and clip loops to secure the pouch to the webbing belt. The firing handle attaches to the outside of the pouch and uses color-coded beads to help distinguish left and right hand units. The handle serves to release the closure system and actuate the CO2 inflation system.

To manually actuate a PECI Tactical Flotation Support System 5326 unit, the user pulls upward on the firing handle. This motion initiates two sequential actions. First the pouch closure pins are released, allowing the pouches to open freely. Second the manual inflator lever is actuated, causing the firing pin to puncture the seal on the CO2 cartridges to release the gas and completely fill the bladder. Should the CO2 inflation system fail to operate, the bladder is filled through an oral inflation tube. This is accomplished by depressing the Oralock valve, then breathing into the tube.

Gas is released from the PECI Tactical Flotation Support System 5326 bladder by pressing downward on the Oralock valve and forcing the air out the oral inflation tube. Once all of the gas is evacuated from the bladder, the CO2 cartridges are replaced, maintenance is performed, and the units are repacked for future use.

Videos

Additional Information

Brand PECI
Video No
FAQ
 

Product FAQ's

Ask a Question

  • What is the part number for the replacement CO2 cartridge used on the TFSS-5326?
    How helpful was this information?

You may also be interested in the following product(s)