Amron International 9201-SGFI System Ground Fault Interrupter

SKU: 9201-SGFI Rate this product

$3,250.00

Availability: Contact us for availability

Click to Enlarge Image

Overview

Features

  • 9201-SGFI offers two separate protection elements from ground fault conditions
  • Isolation transformer is a toroidal design, recognized to UL544 medical grade
  • Transformer has thermal fuse protection and a special shield between the primary and secondary windings
  • Secondary center tap is proved to establish a ground reference for the ground fault detector

Specifications

  • Rated Power: 1800 VA
  • Rated Voltage: 115 VAC
  • Rated Frequency: 50/60 Hz
  • Rated Full Load Current: 15 amps
  • Overload Protection (Circuit Breaker): 15 amps
  • Minimum Trip Current: 1.0 milliamps
  • Trip Time: 16 milliseconds
  • Max Leakage Current Milliamps: <10 milliamps
  • Operating Temperature: -20 to 125 Degrees F
  • Power Cord: 3 Wire, 14 Ga., 15 ft.
  • Dimensions
    • Panel
      • Height: 6 in. (15.2 cm)
      • Width: 8-5/8 in. (21.9 cm)
      • Depth: 3-1/8 in. (7.9 cm)
      • Weight: 3 lbs. (1.36 kg)
    • Transformer
      • Height: 5-3/8 in. (13.6 cm)
      • Width: 10-1/4 in. (26 cm)
      • Depth: 10-1/2 in. (26.6 cm)
      • Weight: 32 lbs. (1.36 kg)
    • System Weight: 44 lbs. (20 kg)
    • 3 Quad Outlet Boxes Distributed Along 20 foot power cord. Weight 9 lbs.

2 or 3 Year Extended Warranties are available for this product. Please refer to the Attachments tab for further information on the program and the Accessories tab to purchase them.

Descriptions

The output of the Amron International 9201-SGFI System Ground Fault Interrupter is floating, neither side, (high line or neutral) is tied to the ground. The isolation transformer is a toroidal design, recognized to UL544 medical grade. The transformer has thermal fuse protection and a special shield between the primary and secondary windings. A secondary center tap is proved to establish a ground reference for the ground fault detector.

The ground fault interrupter module is a current sense design which monitors the current out of the unit and the return current. The two currents cancel each other out and a sense amplifier monitors the difference. If the current difference exceeds a predetermined value, a disconnect relay shuts down the AC power.