Amron International 8890-100 Oxygen Treatment Hood with Tubing and Humidifier

Be the first to review this product

SKU: 8890-100

$186.00

Availability: Contact us for availability

Amron International Oxygen Treatment Hood

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • Amron International Oxygen Treatment Hood
  • Amron International 8890-100 Oxygen Treatment Hood with Tubing and Humidifier
  • Amron International Oxygen Treatment Hood with Panel Drawing
  • Amron International Oxygen Treatment Hood Parts List

You may also be interested in the following product(s)

Overview

Features

  • CE Registered
  • Optimum cooling and noise reduction
  • Reusable neck ring (autoclavable)
  • Conveniently located hoses reduce bulk and improve comfort
  • Designed for simplicity, performance, economy, ease-of-use and safe effective cleaning.
  • Innovative design allows patient to recline comfortably
  • Multi-purpose port for gas analysis or entertainment option
  • Positive o-ring seal between hood and neck ring
  • Soft vinyl hood with extra large optical quality window
  • Replaceable surgical latex neck seal with sized trim lines
  • Optional entertainment system with pneumatic headset

Sterilization

  • Please reference the Cleaning Manual located in the Attachments Tab on this Web Page for recommended cleaning instructions
  • Hood Part Number 8891-010 can also be sterilized using either gas sterilization method listed below; however multiple cycles of gas sterilizing over time will shorten the products working life:
    • Low - 4  hours at 100 degrees with an aeration time of 36 hours
    • High - 1 hour at 130 degrees with an aeration time of 12 hours
    • Hood cannot be autoclaved
  • Neck Ring Part Number 8891-001 can be gas sterilized and/or autoclaved with little or no effect on the product - Please note that the o-ring and plug need to be removed prior to autoclaving.

Note: This product may contain natural rubber latex which can cause allergic reactions. Please select the Medical Grade Neoprene/Non-Latex model if you believe you may have an allergy.

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician or licensed practitioner.

Descriptions

Amron's critically acclaimed and celebrated 8890-100 Oxygen Treatment Hood with Tubing and Humidifier is the preeminent hood on the market and easily sets the standard for all others. Offering extreme versatility and ease-of-use, Amron's Oxygen Treatment Hood (8891) was designed as an efficient, cost-effective operation within a multi-place hyperbaric chamber. The heart of the system is the reusable neck ring with conveniently located supply and exhaust hoses with accompanying o-ring seal for the vinyl hood attachment. While the neck ring was developed to withstand multiple cycles in an autoclave, the neck seal features an integrated o-ring for easy replacement and has numbered trim rings for accurate neck sizing.

What's more, the supply and exhaust locations allow oxygen to circulate easily throughout the hood at reduced noise levels. As a soft flow of gas helps to cool the patient, the optical-quality viewing window is continuously being defogged. The optional pneumatic entertainment system allows patients to listen to monaural music or video sources in complete comfort. A patient-operated volume control and channel selector switch eliminates the need to disturb attending nurses or chamber operators. No electrical power is ever supplied directly to the hood, which ensures safe operation and peace of mind.

Attachments
Videos

Additional Information

Brand Amron International
Video No
FAQ
 

Product FAQ's

Ask a Question

  • What is your official recommended oxygen flow rate for the Amron patient hyperbaric oxygen treatment hood?

    Adjust all the appropriate flow control devices between 25-50 liters per minute. As the hood inflates, adjust the supply and exhaust flow controls to stabilize the hood pressure.

    NOTE: Excessive flow will overinflate the hood, and insufficient flow will collapse the hood. Flow rates will vary with chamber delivery systems, user lung volume, and breathing rate. Proper Oxygen and Carbon Dioxide levels should be verified within the hood through the multi-purpose port and the use of an Oxygen analyzer and Carbon Dioxide analyzer such as the Analox 1000 Oxygen Monitor and Analox 5001 Carbon Dioxide Monitor.

    How helpful was this information?

  • Can I purchase an Oxygen Treatment Hood for private use?
    No, Federal law (USA) mandates that Amron can only sell this device to physicians and/or licensed clinical practitioners.
    How helpful was this information?

  • What is the internal volume of the Oxygen Treatment Hood?
    1533.98 in³.
    How helpful was this information?

  • The method of cleaning as stated in the general instructions does not suit our unit due to the clean area that would be required to drip dry the hoods. Is there any other approved method of cleaning?

    We only have two methods approved for cleaning.

    1)     The first is spraying Sanizide and letting the hood sit for 10 minutes.

    2)    The second is gas sterilization using the method below:

    1. Low - 4  hours at 100 degrees with an aeration time of 36 hours
    2. High - 1 hour at 130 degrees with an aeration time of 12 hours

    Using the gas sterilization will shorten the life of the hood but we have many customers that use it and are very happy with the results.

     